Steel frame Table form lift TL 1512
213300043
97
11.3 Maintenance plan
In the following section the maintenance tasks necessary for an
optimal and trouble free operation are described.
If an increase in wear and tear is detected during the regular
inspections the maintenance intervals should be shortened
according to the actual signs of wear.
For queries on maintenance work and intervals contact the
manufacturer, see page 2 for the service address.
NOTE!
The information below refers to the daily use during
a single work shift. If using the system continuously
or during several shifts, the maintenance intervals
are considerably shorter. Please contact the
manufacturer, see page 2.
Interval
Description
Task
Comment
To be
performed by
weekly
Instruction and load
sticker
Visual inspection
whether mounted and
legible
Operator
EMERGENCY OFF
button on platform,
ground station
Function check
The lift must be
completely inoperable if
the EMERGENCY OFF
button is pressed.
Operator
Limit switch on platform
gate, ramps
Function check
The lift must not start to
move if the doors,
ramps are open
Operator
Trailing cable
Use talcum powder to
coat the cable.
Check for damage.
Operator
FI circuit breaker
Trigger and check
function
Customer
service
technician
Grease pump
Add lubricant
Adhesive lubricant
OKS495, from OKS
Customer
service
technician
Load position gates
Inspect locking devices
The lift must not start to
move if the loading
position doors are open
Operator
Содержание TL 1512
Страница 18: ...Steel frame Table form lift TL 1512 18 213300043 3 Design and function 3 1 Overview Fig 7 Overall view...
Страница 19: ...Steel frame Table form lift TL 1512 213300043 19 Fig 8 Top view 19...
Страница 78: ...Steel frame Table form lift TL 1512 78 213300043 8 3 1 Illustration of loading points...
Страница 113: ...Steel frame Table form lift TL 1512 213300043 113 17 Appendix 17 1 Lift truck data sheet EJB 213 EHW Table...
Страница 114: ...Steel frame Table form lift TL 1512 114 213300043...