background image

Atmospheric Gas  

Page 19

Page 18 

Atmospheric Gas 

SECTION VIII: PARTS LIST (cont .)

2

6

3

5

4

2

1

Table Y: ezFIT Burner Parts  

1

Burner

2

Pilot Kit

3

Main Burner Tube

4

Pilot Tube

5

Thermocouple

6

Orifice (Natural or LP)

P

Paarrtt  D

Deessccrriippttiioonn

Figure 8: 

ezFIT Burner Parts

Table 5: 

ezFIT Burner Parts

SECTION IX: WARRANTY

LIMITED WARRANTY FOR GAS-FIRED WATER HEATER

Bock Water Heaters, Inc.

110 S. Dickinson Street

Madison, WI 53703

Phone: 608-257-2225

WHAT DOES THIS LIMITED WARRANTY COVER?

This limited warranty applies only to the original consumer purchaser.

General Defects and Malfunctions: This warranty covers defections and malfunctions in your 

new water heater for a period of one year from the original installation date. We will repair or 

replace, at our option, any defective or malfunctioning component of the water heater.  This 

limited warranty will terminate if you sell or otherwise transfer the water heater, or the water 

heater is installed at a location different from its original installation location.

Tank and Heat Exchanger: We also warrant that the tank and heat exchanger will not leak 

due to defective materials or workmanship for five years from the date of original installation 

or from date of manufacture in the event the Limited Warranty Registration Card was not 

completed and returned to manufacturer. If the tank and heat exchanger is leaking and we 

have verified that the leak is due to a defect in materials and workmanship, we will replace 

the tank with a tank that is the nearest Bock model available at the time of replacement. If 

a replacement tank is provided, it will remain warranted under this section as if it were the 

original tank. For example, if we send you a replacement tank under this limited warranty 

two years after the original installation date, then the replacement tank will remain warranted 

for the remaining three years after the original installation date.

HOW DO YOU GET SERVICE UNDER THE LIMITED WARRANTY?

In order for the warranty period to begin on the date of installation, you must return the 

warranty registration card attached below within 30 days of purchasing the water heater. You 

may also register your water heater online at www.bockwaterheaters.com. You must have a 

copy of the original sales receipt at the time you request service. Failure to return the warranty 

registration card and provide a copy of the sales receipt will result in the warranty period 

beginning from the date of manufacture.

To get service under this limited warranty you should contact either the dealer or installer. If 

dealer or installer is unknown you can contact us via e-mail at warranty@bockwaterheaters.

com or call us Monday through Friday between the hours of  

8 o’clock a.m. to 5 o’clock p.m. Central Time at the following number: 1-608-257-2225.

You can also write us at the following address: 

Bock Water Heaters, Inc.

Warranty Support Group

110 S. Dickinson Street

Madison, WI 53703

We will respond not later than ten days after we have received your request for service.

Содержание EzFit EZ 100-76

Страница 1: ...perature is needed in part of the water system automatic temperature limiting devices must be used on all lines to water taps WARNING Flammable vapors may be drawn to this water heater from other areas of the structure by air currents Do not store or use any flammable liquids in the vicinity of this heater WARNING Water heater blankets may restrict air flow to the water heater and cause fire asphy...

Страница 2: ...ection III Pre Installation 7 Section IV Installation 10 Section V Operation 13 Section VI Maintenance 15 Section VII Troubleshooting 16 Section VIII Parts List 17 Section IX Warranty 19 DANGER Water heaters utilizing Liquefied Petroleum gas LP are different from natural gas models A natural gas heater will not function safely on LP gas and vice versa To avoid possible equipment damage personal in...

Страница 3: ...rature becomes excessive 200 F the ECO will shut off all gas to the water heater If an ECO has detected an over temperature condition and has opened the control will not function and a replacement will be required The thermostat is factory set at 120 F See Figure 6 for thermostat letter and temperature relationships If hotter water is required a tempering device or anti scald device must be instal...

Страница 4: ...ing of the lever or the normal operation of the T P valve If it is not piped to a proper drain If the valve fails to flow water or reseat call your plumber The T P valve is factory installed A discharge drain tube must be installed responsibility of the installer and shall terminate plain not threaded 6 inches above the floor drain The drain tube material must be approved for temperatures of 120o ...

Страница 5: ...tu hr of the combined total input of all fuel burning appliances in the space Each opening shall have an area of not less than 100 square inches or a minimum dimension of not less than 3 inches Figure 2 SECTION III PRE INSTALLATION cont CONFINED SPACE CONT B Outside Air Supply Confined spaces shall be provided with two permanent openings one within 12 inches of the top and one within 12 inches of ...

Страница 6: ...e the National Fuel Gas Code NFPA 54 DANGER Substitution elimination or relocation of the draft hood will result in unsafe operation and void the warranty of your water heater Improper venting or misuse of the draft hood can result in unsafe operation causing bodily injury explosion fire or death To avoid the risk of fire explosion or asphyxiation from carbon monoxide NEVER operate this water heat...

Страница 7: ...d remain lit If it goes out repeat steps 3 through 8 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal in...

Страница 8: ...be measured and monitored Run water out of the tap nearest the heater until it comes out warm Using a calibrated thermometer take a measurement If the water is not at a suitable temperature for the installation have a qualified service person adjust the temperature control Contact Bock for further information if needed This log or a similar one should be filled out as follows Date Time Person runn...

Страница 9: ... Tighten connection at thermostat 1 Refer to lighting instructions 1 Gas control knob not positioned correctly 2 Air in gas line 2 Purge gas line 3 Excessive water temperature and pilot failure 3 Replace thermostat Water too hot or not hot enough 1 Thermostat set too high or low 1 Adjust setting as required 2 Thermostat out of calibration 2 Replace thermostat Insufficient hot water Rumbling noise ...

Страница 10: ...e leak is due to a defect in materials and workmanship we will replace the tank with a tank that is the nearest Bock model available at the time of replacement If a replacement tank is provided it will remain warranted under this section as if it were the original tank For example if we send you a replacement tank under this limited warranty two years after the original installation date then the ...

Страница 11: ...t somewhere else Fail to follow the care and maintenance instructions provided with the water heater Remove the anode rods Fail to inspect and replace the anode rods you must retain and present your paid receipts as proof of anode rod replacement HOW DOES STATE LAW RELATE TO THIS LIMITED WARRANTY This is a limited warranty WE MAKE NO OTHER EXPRESS WARRANTIES WITH RESPECT TO THIS WATER HEATER We wi...

Отзывы: