SECTION IX: WARRANTY

LIMITED WARRANTY FOR GAS-FIRED WATER HEATER

Bock Water Heaters, Inc.

110 S. Dickinson Street

Madison, WI 53703

Phone: 608-257-2225

WHAT DOES THIS LIMITED WARRANTY COVER?

This limited warranty applies only to the original consumer purchaser.

General Defects and Malfunctions: This warranty covers defections and malfunctions in your
new water heater for a period of one year from the original installation date. We will repair or
replace, at our option, any defective or malfunctioning component of the water heater.  This
limited warranty will terminate if you sell or otherwise transfer the water heater, or the water
heater is installed at a location different from its original installation location.

Tank and Heat Exchanger: We also warrant that the tank and heat exchanger will not leak due
to defective materials or workmanship for five years from the date of original installation or
from date of manufacture in the event the Limited Warranty Registration Card was not
completed and returned to manufacturer. If the tank and heat exchanger is leaking and we
have verified that the leak is due to a defect in materials and workmanship, we will replace
the tank with a tank that is the nearest Bock model available at the time of replacement. If a
replacement tank is provided, it will remain warranted under this section as if it were the
original tank. For example, if we send you a replacement tank under this limited warranty
two years after the original installation date, then the replacement tank will remain
warranted for the remaining three years after the original installation date.

HOW DO YOU GET SERVICE UNDER THE LIMITED WARRANTY?

In order for the warranty period to begin on the date of installation, you must return the
warranty registration card attached below within 30 days of purchasing the water heater. You
may also register your water heater online at www.bockwaterheaters.com. You must have a
copy of the original sales receipt at the time you request service. Failure to return the warranty
registration card and provide a copy of the sales receipt will result in the warranty period
beginning from the date of manufacture.

To get service under this limited warranty you should contact either the dealer or installer. If
dealer or installer is unknown you can contact us via e-mail at
[email protected] or call us Monday through Friday between the hours of 
8 o’clock a.m. to 5 o’clock p.m. Central Time at the following number: 1-608-257-2225.

You can also write us at the following address: 

Bock Water Heaters, Inc.
Warranty Support Group
110 S. Dickinson Street
Madison, WI 53703

We will respond not later than ten days after we have received your request for service.

Содержание 55602

Страница 1: ...perature is needed in part of the water system automatic temperature limiting devices must be used on all lines to water taps WARNING Flammable vapors may be drawn to this water heater from other area...

Страница 2: ...property damage personal injury or death DANGER Water heaters utilizing Liquefied Petroleum gas LP are different from natural gas models A natural gas heater will not function safely on LP gas and vi...

Страница 3: ...tion I Specifications 4 Section II General Information 5 Section III Pre Installation 7 Section IV Installation 10 Section V Operation 13 Section VI Maintenance 15 Section VII Troubleshooting 16 Secti...

Страница 4: ...to LP Working Pressure 150 PSI 1034 kPa Test Pressure 300 PSI 2068kPa For natural gas Manifold pressure 4 W C 1 00 kPa Inlet pressure range 5 14 W C 1 25 3 49 kPa For propane gas Manifold pressure 10...

Страница 5: ...setting is 180 F A built in non cycling Energy Cut Off ECO is standard on all gas thermostats In the event that the water temperature becomes excessive 200 F the ECO will shut off all gas to the water...

Страница 6: ...tures in this water heater install temperature and pressure protective equipment required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally...

Страница 7: ...er or to lower floors of the structure When such location cannot be avoided a suitable drain pan must be installed under the water heater The drain pan depth must be suitable for draining and collecti...

Страница 8: ...y result if the room does not have an adequate air supply See National Fuel Gas Code NFPA 54 or the discussions of Unconfined Space and Confined Space below Poor ventilation will also result in hot sp...

Страница 9: ...inimum of 6 feet Shorter vent heights could result in unstable draft and nuisance lock outs The venting system should be sized according to National Fuel Gas Code NFPA 54 ANSI Z223 1 most recent editi...

Страница 10: ...on the water heater Install a union and shut off valve at both potable water connections All piping should be 3 4 diameter new copper or larger A tempering valve or anti scald valve should be install...

Страница 11: ...hut off valve to check incoming gas pressure During pressure testing of the gas supply piping close the manual gas shut off valve to the water heater Test pressure shall not exceed 1 2 PSIG 14 W C The...

Страница 12: ...n Gas Thermostat Sediment Trap Drain Valve HeatTrap 6 min HeatTrap 6 min Figure 4 Recommended Water Gas Vent Connections SECTION IV INSTALLATION cont DRAFT HOOD INSTALLATION 1 Locate the two predrille...

Страница 13: ...ny part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal inj...

Страница 14: ...t off of gas then set thermostat to the highest temperature The main burner should relight Set thermostat to the lowest temperature the main burner should go out The thermostat should be adjusted to t...

Страница 15: ...hould be inspected twice in the first year and at least yearly once a time interval for inspection has been developed It is recommended to check the rod s six months after the heater is installed If t...

Страница 16: ...e em m P Po os ss si ib bl le e c ca au us se es s R Re ec co om mm me en nd de ed d A Ac ct ti io on n Cannot light pilot 5 Pilot tube leaking 5 Tighten connection at thermostat 1 Refer to lighting i...

Страница 17: ...2 2 9 7 8 1 Hot Outlet Nipple 6 Gas Thermostat 2 Anode Rods 7 Inner Access Door 3 Draft Hood 8 Insulation 4 Dip Tube 9 Outer Access Door 5 T P Relief Valve 10 Drain Valve P Pa ar rt t D De es sc cr r...

Страница 18: ...N VIII PARTS LIST cont 2 6 3 5 4 2 1 1 Burner 2 Pilot Kit 3 Main Burner Tube 4 Pilot Tube 5 Thermocouple 6 Orifice Natural or LP P Pa ar rt t D De es sc cr ri ip pt ti io on n Figure 8 ezFIT Burner Pa...

Страница 19: ...of replacement If a replacement tank is provided it will remain warranted under this section as if it were the original tank For example if we send you a replacement tank under this limited warranty t...

Страница 20: ...somewhere else Fail to follow the care and maintenance instructions provided with the water heater Remove the anode rods Fail to inspect and replace the anode rods you must retain and present your pa...

Отзывы: