WARNING

Improper installation, adjustment, alteration,
service or maintenance can cause serious
injury or property damage. Refer to this
manual. For assistance or additional
information, consult a qualified installer or
service agency.

WARNING

If the information in these instructions is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or
death.

WARNING

Do not install on combustible flooring. Install
in accordance with all local codes. In the
 absence of local codes, refer to ANSI
223.1/NFPA 54 and/or CSA B149.1.

CAUTION

The recommended temperature for normal
residential use is 120°F. The dial on the aquastat
does not always reflect the out-coming water
temperature and it could occasionally exceed
120°F. Variation in out-coming temperature
could be based on factors including but not
limited to usage patterns and type of installa-
tion. Test water at the tap nearest to the water
heater. See page 9 for measuring the out-
 coming water temperature.

WARNING

Hotter water increases the risk of scald injury.
Before adjusting the water temperature setting,
read this instruction manual. Temperatures at
which injury occurs vary with the person’s age
and the length of exposure. The slower
reaction time of children, elderly or physically
or mentally challenged persons increases the
scalding hazard to them. It is recommended
that lower water temperatures be used where
these exposure hazards exist. Households with
small children or invalids may require a
temperature setting less than 120°F to prevent
accidental contact with hot water. 

To produce

less than 120°F, use point-of-use
temperature limiting devices.

!

!

!

!

!

If higher water temperature is needed in part
of the water system, automatic temperature
limiting devices must be used on all lines to
water taps.

WARNING

Flammable vapors may be drawn to this water
heater from other areas of the structure by air
currents. Do not store or use any flammable
liquids in the vicinity of this heater.

WARNING

Water heater blankets may restrict air flow to
the water heater and cause fire, asphyxiation,
personal injury or death.

THIS MANUAL HAS BEEN PREPARED TO

 ACQUAINT YOU WITH THE INSTALLATION,

OPERATION, AND MAINTENANCE OF YOUR

WATER HEATER AND TO PROVIDE IMPORTANT

SAFETY INFORMATION.

Read all instructions thoroughly before
attempting installation or operation of your
water heater. Keep these instructions for future
reference.

Local plumbing and electrical codes must be
followed in the installation of this water
heater. In the absence of a local code use the
UNIFORM PLUMBING CODE and the NFPA
Code. Local codes may supersede instructions
in this installation manual.

These instructions are a guide for the correct
installation of the water heater. The manufac-
turer will not be liable for damages caused by
failure to comply with the installation and 
operating instructions outlined on the 
following pages.

Installation, testing, and replacement of gas
piping, appliances, or accessories, and repair
and servicing of equipment, shall be
performed only by a qualified agency.

FAILURE TO FOLLOW THESE INSTRUCTIONS

OR ALL APPLICABLE BUILDING CODES 

AND REGULATIONS VOIDS THE WARRANTY

ON THIS WATER HEATER.

!

!

Warranty, Registration Card and Parts List are included.

Homeowner: Please remember to return the Registration Card!

To the Consumer:

Please read these and all component 
instructions and keep for future reference.

To the Installer:

Please attach these instructions 
next to the water heater.

Rev4 6/16

Atmospheric Gas 

Instruction Manual

23405

EZ 75-76, EZ 100-76

Содержание 55602

Страница 1: ...perature is needed in part of the water system automatic temperature limiting devices must be used on all lines to water taps WARNING Flammable vapors may be drawn to this water heater from other area...

Страница 2: ...property damage personal injury or death DANGER Water heaters utilizing Liquefied Petroleum gas LP are different from natural gas models A natural gas heater will not function safely on LP gas and vi...

Страница 3: ...tion I Specifications 4 Section II General Information 5 Section III Pre Installation 7 Section IV Installation 10 Section V Operation 13 Section VI Maintenance 15 Section VII Troubleshooting 16 Secti...

Страница 4: ...to LP Working Pressure 150 PSI 1034 kPa Test Pressure 300 PSI 2068kPa For natural gas Manifold pressure 4 W C 1 00 kPa Inlet pressure range 5 14 W C 1 25 3 49 kPa For propane gas Manifold pressure 10...

Страница 5: ...setting is 180 F A built in non cycling Energy Cut Off ECO is standard on all gas thermostats In the event that the water temperature becomes excessive 200 F the ECO will shut off all gas to the water...

Страница 6: ...tures in this water heater install temperature and pressure protective equipment required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally...

Страница 7: ...er or to lower floors of the structure When such location cannot be avoided a suitable drain pan must be installed under the water heater The drain pan depth must be suitable for draining and collecti...

Страница 8: ...y result if the room does not have an adequate air supply See National Fuel Gas Code NFPA 54 or the discussions of Unconfined Space and Confined Space below Poor ventilation will also result in hot sp...

Страница 9: ...inimum of 6 feet Shorter vent heights could result in unstable draft and nuisance lock outs The venting system should be sized according to National Fuel Gas Code NFPA 54 ANSI Z223 1 most recent editi...

Страница 10: ...on the water heater Install a union and shut off valve at both potable water connections All piping should be 3 4 diameter new copper or larger A tempering valve or anti scald valve should be install...

Страница 11: ...hut off valve to check incoming gas pressure During pressure testing of the gas supply piping close the manual gas shut off valve to the water heater Test pressure shall not exceed 1 2 PSIG 14 W C The...

Страница 12: ...n Gas Thermostat Sediment Trap Drain Valve HeatTrap 6 min HeatTrap 6 min Figure 4 Recommended Water Gas Vent Connections SECTION IV INSTALLATION cont DRAFT HOOD INSTALLATION 1 Locate the two predrille...

Страница 13: ...ny part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal inj...

Страница 14: ...t off of gas then set thermostat to the highest temperature The main burner should relight Set thermostat to the lowest temperature the main burner should go out The thermostat should be adjusted to t...

Страница 15: ...hould be inspected twice in the first year and at least yearly once a time interval for inspection has been developed It is recommended to check the rod s six months after the heater is installed If t...

Страница 16: ...e em m P Po os ss si ib bl le e c ca au us se es s R Re ec co om mm me en nd de ed d A Ac ct ti io on n Cannot light pilot 5 Pilot tube leaking 5 Tighten connection at thermostat 1 Refer to lighting i...

Страница 17: ...2 2 9 7 8 1 Hot Outlet Nipple 6 Gas Thermostat 2 Anode Rods 7 Inner Access Door 3 Draft Hood 8 Insulation 4 Dip Tube 9 Outer Access Door 5 T P Relief Valve 10 Drain Valve P Pa ar rt t D De es sc cr r...

Страница 18: ...N VIII PARTS LIST cont 2 6 3 5 4 2 1 1 Burner 2 Pilot Kit 3 Main Burner Tube 4 Pilot Tube 5 Thermocouple 6 Orifice Natural or LP P Pa ar rt t D De es sc cr ri ip pt ti io on n Figure 8 ezFIT Burner Pa...

Страница 19: ...of replacement If a replacement tank is provided it will remain warranted under this section as if it were the original tank For example if we send you a replacement tank under this limited warranty t...

Страница 20: ...somewhere else Fail to follow the care and maintenance instructions provided with the water heater Remove the anode rods Fail to inspect and replace the anode rods you must retain and present your pa...

Отзывы: