![BOC Smootharc Elite TIG 230 AC/DC Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/boc/smootharc-elite-tig-230-ac-dc/smootharc-elite-tig-230-ac-dc_operating-instructions-manual_2781955033.webp)
Design and function
TIG welding
099-000143-BOC01
16.11.2009
33
Non-latched mode
NOTE
When the
foot-operated remote control
RTF is connected, the machine switches
automatically to non-latched operation.
The up- and down-slopes are switched off.
I
I
start
AMP
t
Up
1.
2.
t
Down
I
end
t
AMP%
Figure 5-9
1st cycle:
• Press and hold torch trigger 1.
• The gas pre-flow time elapses.
• HF ignition pulses jump from the electrode to the workpiece, the arc ignites.
• The welding current flows and immediately assumes the value set for the ignition current I
start
.
• HF is switched off.
• The welding current increases with the adjusted up-slope time to the main current AMP.
Switching from main current AMP to secondary current AMP%:
Press torch trigger 2 or Tap torch trigger 1 *
2nd cycle:
• Release torch trigger 1.
• The main current falls in the set down-slope time to the
end-crater current I
end
(minimum current).
If the 1st torch trigger is pressed during the down-slope time, the welding current returns to the
main current AMP set.
• The main current reaches the end-crater current I
end
, the arc extinguishes.
• The set gas post-flow time elapses.
*
Tapping function:
Tap briefly on the torch trigger to initiate a function change, e.g. changeover from main to
secondary current (for more in-depth information, see chapter "Setting the torch mode and
up/down speed").