STORAGE AND DISPOSAL
6.1
Storage
Use the procedure below to store the EO pump:
1.
Shut down the pump as described in Section 4.6.
2.
Isolate the pump from the electrical supply, disconnect it from your vacuum system and drain the
pump fluid as described in Section 5.4.
3.
Clean and reassemble the pump as described in Section 5.6. Do not refill the pump with fluid.
4.
Place protective covers over the inlet and outlet-flanges and the cooling-water supply and return
connectors.
5.
Store the pump in cool dry conditions until it is required for use. When required, prepare and install
the pump as described in Section 3.
6.2
Disposal
Dispose of the EO pump and any components removed from it safely in accordance with all local and
national safety and environmental requirements.
Take particular care with the following:
•
Components which have come into contact with pump fluid.
•
Fluoroelastomers which may have been subjected to temperatures above 315
o
C (see Section 5.1).
•
Breakdown products which may be present if the pump fluid has been subjected to temperatures
above the fluid breakdown temperature.
•
Components which have been contaminated with dangerous process substances.
WARNING
Wear the appropriate personal protective equipment when you dispose of pump fluid,
and components which have come into contact with pump fluid or been contaminated
with dangerous process substances.
Содержание EO2K
Страница 1: ...B304 09 880 Issue G Original Instruction Manual EO2K EO4K and EO6K Diffusion Pumps ...
Страница 2: ...This page intentionally blank ...
Страница 6: ...EO2K EO4K and EO6K Diffusion Pumps PAGE iv Issue G iv Aug 06 This page intentionally blank ...
Страница 14: ...EO2K EO4K and EO6K Diffusion Pumps PAGE 8 Issue G 8 Aug 06 This page intentionally blank ...
Страница 20: ...EO2K EO4K and EO6K Diffusion Pumps TECHNICAL DATA PAGE 14 Issue G 14 Aug 06 Figure 10 EO6K dimensions mm ...
Страница 22: ...EO2K EO4K and EO6K Diffusion Pumps PAGE 16 Issue G 16 Aug 06 This page intentionally blank ...
Страница 36: ...EO2K EO4K and EO6K Diffusion Pumps PAGE 30 Issue G 30 Aug 06 This page intentionally blank ...
Страница 52: ...EO2K EO4K and EO6K Diffusion Pumps PAGE 46 Issue G 46 Aug 06 This page intentionally blank ...
Страница 54: ...EO2K EO4K and EO6K Diffusion Pumps PAGE 48 Issue G 48 Aug 06 This page intentionally blank ...
Страница 58: ...EO2K EO4K and EO6K Diffusion Pumps PAGE 52 Issue G 52 Aug 06 This page intentionally blank ...
Страница 61: ...This page intentionally blank ...