Feb 04
Issue A
18B4B Vapour Booster Pumps
PAGE
31
31
OP
ERATION
3.
Turn the set screw anticlockwise again by
3
/
4
of
a complete turn (270
o
); one complete
anticlockwise revolution of the screw (in the
direction of the arrow, 4) is equivalent to an
increase in the operating temperature of
approximately 40
o
C.
4.
When you have set the snap-switch, tighten the
locking screw (3).
5.
Restart the pump.
Figure 11 - Adjust the boiler protection thermal snap-switch
1. Electrical wires
2. Temperature set-screw
3. Locking screw
4. Arrow
5. Mounting sleeve
6. Snap-switch body