Issue A
Feb 04
PAGE
12
18B4B Vapour Booster Pumps
TECHNIC
A
L
D
A
TA
12
Figure 3 - Dimensions (mm): key
1. Inlet
2. Cooling-water inlet
3. Outlet
4. Cooling-water outlet
5. Cooling-fail thermal snap-switches
6. Clearance required to remove heaters
7. Fluid low level switch (optional)
8. Electrical box
9. Earth (ground) stud
10. Pt100 temperature probe (optional)
11. Fluid drain connection
12. Identification and rating plate
13. Hot surfaces: temperatures below this line can reach 250
o
C
14. Fixing holes (3 off): Ø17.5 on 549 PCD
15. ISO inlet
16. EHVI inlet
17. ANSI inlet
18. ANSI outlet (8 holes Ø19.2 on 190.5 PCD)
19. ISO outlet (8 holes Ø11.2 on 200 PCD)
20. EHVI outlet (2 inch union nut and tailpiece, counter-bored
Ø54.1-54.18 x 19.4, 20.2 deep)
21. Boiler protection thermal snap-switch
22. Fixing holes:
12 holes Ø14 on 395 PCD (ISO inlet)
12 holes Ø25.4 on 431.8 PCD (ANSI inlet)
8 holes Ø11 on 387.4 PCD (EHVI inlet)
ØA
ØB
C
ANSI
482.6
228.6
807
ISO
425
225
807
EHVI
406
178
810
Содержание 18B4B
Страница 1: ...B065 10 880 Issue A Original Instruction Manual 18B4B Vapour Booster Pumps...
Страница 2: ...This page intentionally blank...
Страница 11: ...Feb 04 Issue A 18B4B Vapour Booster Pumps PAGE 5 5 INTRODUCTION Figure 1 Part sectional view of the 18B4B pump...
Страница 12: ...Issue A Feb 04 18B4B Vapour Booster Pumps PAGE 6 6 This page intentionally blank...
Страница 19: ...Feb 04 Issue A 18B4B Vapour Booster Pumps PAGE 13 13 TECHNICAL DATA Figure 3 Dimensions mm...
Страница 20: ...Issue A Feb 04 18B4B Vapour Booster Pumps PAGE 14 14 This page intentionally blank...
Страница 40: ...Issue A Feb 04 18B4B Vapour Booster Pumps PAGE 34 34 This page intentionally blank...
Страница 54: ...Issue A Feb 04 18B4B Vapour Booster Pumps PAGE 48 48 This page intentionally blank...
Страница 56: ...Issue A Feb 04 18B4B Vapour Booster Pumps PAGE 50 50 This page intentionally blank...
Страница 61: ...This page intentionally blank...