3
2
1. Conduit is recommended when tracking the supply line through walls, etc
2. To ensure effective operation of soap valve, supply line should be no greater than
1.4m from pump.
3. Thread sealing tape such as Teflon tape or similar is recommended as a sealant
on the exposed thread of the adapter where the valve attaches.
4. Soap Reservoir should always be covered to avoid dust & grit from
contaminating the soap and fouling the dispenser. RBA recommends using part
RBA7730-999-001 Rubber Grommet to house the supply line as it enters the
reservoir.
5. To avoid crushing the reservoir, the lid of the reservoir should be only lightly
tightened, allowing a minute passage of air in, as soap is drawn out.
6. To ensure effective operation of soap valve, supply line should have no crimps or
bends. Extra attention should be paid to the supply tube as it turns down from the
rear of the valve. Also, installers should ensure an additional ‘duck-bill valve’ [part #
B111-15] is inserted into the end of the supply line to assist in maintaining prime.
7. Easy access to the rear of the valve should be provided to allow for maintenance
and repair.
8. Part numbers for remote reservoirs as follows:
RBA7730-999-005
Soap Reservoir, 5L
RBA7730-999-010
Soap Reservoir, 10L
INSTALLATION
Soap Solution shall be dispensed in a liquid form and should be:
(a) vegetable oil based;
(b) anhydrous soap concentration range: 10% - 15%;
(c) specific gravity range: 1.0 - 1.1;
(d) viscosity range: max 1.0 centerpoise;
(e) soap shall contain a humectant (anti coagulant);
(f)
soap shall be perfumed or non perfumed.
IMPORTANT:
IF THE SOAP DOES NOT MEET THIS SPECIFICATION THE
WARRANTY WILL BE VOID.
LIQUID SOAP SPECIFICATION - RBA7737-106
85mm
3-1/4''
Adapter
Bottle Cap
50mm
2''
Maximum
Panel
Thickness
Container
Container Support
Not Furnished
85mm
Dia.
3-5/16''
230mm
9-1/16''
Washer
Nut
Cable Tie
Supply Tube
(1400mm)
Valve
ROUGH IN DIMENSION
Panel Depth: 32mm - 50mm
Penetration: 18mm
Clearance behind wall: 90mm