CAUTION:
READ ALL WARNINGS BEFORE USING OR ATTEMPTING ANY WORK ON
YOUR MARKER. SHOULD YOU BE UNSURE AT ANY POINT, STOP AND SEEK
PROFESSIONAL SUPPORT.
Setting Pressures Using the Pressure Tester
Setting the pressures after regulator service is the best method to get your marker performing well.
The LPR controls marker cycling and contributes to noise and kick experienced when firing the
marker. Setting the LPR too low will result in problems with consistency. The HPR controls the
velocity of the marker. Once you have performed the initial settings use a chronograph to fine tune
the marker’s velocity.
1.
Remove the LPR by unscrewing
counterclockwise from the front of the
marker
2.
Screw the tester into the marker body.
Then screw the LPR into the front of the
tester.
3.
The tester has two gauges opposing each
other. The HPR reads to 300 psi and the
LPR gauge reads to 160 psi.
4.
Connect air system to the marker and
turn on the air by screwing the knob at
the front of the Air Source Adapter (ASA)
in clockwise.
5.
Turn on the marker by pressing the
button on the back of the frame.
Pressing and holding for one full second
will disable the eye system without
turning off the board.
6.
Set the HPR pressure first by turning the
adjustment screw in the bottom of the
regulator. Turning the screw clockwise
increases the pressure and therefore the
velocity. Turning it counterclockwise
will lower the pressure and velocity.
Only turn the wrench in small
increments – for example 1/16
th
-1/8
th
of
a turn with each adjustment. NOTE:
While adjusting the regulators pull the
trigger to allow pressures to equalize
when you decrease either setting. Set
the HPR 165 to 185 PSI. A suggested
initial setting is 180 PSI.
7. After adjusting the HPR, adjust the LPR
by turning the adjustment screw on the
front of the LPR. Adjust the LPR using
small increments – 1/8 of a turn at a time.
Keep pulling the trigger while making the
adjustment to allow pressure to equalize.
Set the LPR pressure between 65 and 75
PSI. A suggested initial setting is 70 PSI.
1
2