Boann Reverse Osmosis 5-Stage Water Filtration System Скачать руководство пользователя страница 18

18

boannstyle.com

Testing the Water Filtration System

After letting the system operate for one (1) hour, turn On the filtration system faucet and let water 

run from the faucet until the storage water tank is empty. Invariably at first you will evaluate dark, 

murky water coming from the faucet. This is normal and reflects loose particulates and carbon 

dust being flushed out from the system. Upon conclusion of emptying out the tank, water will 

commence to trickle from the faucet, indicating the tank is empty. After this process, turn Off the 

faucet and let the system fill with water. The system is now operational and thus will produce 

clean, drinkable water. 

This concludes the installation process and you may now start drinking purified water from the 

Boann Reverse Osmosis 5-Stage Water Filtration System. Enjoy! 

If you require further information and/or clarification regarding the installation process, please 

feel free to contact Boann at: 

[email protected].

Threaded Fittings

To prevent a leak on any threaded fitting that screws into the 

Reverse Osmosis 5-Stage Water Filtration System, please 

employ Teflon tape by way of wrapping the threads of the 

various threaded fittings 5-7 times.

This preventative measure will assist in preventing potential 

leaks from the threaded fittings throughout the R.O. filtration 

system. 

If there are signs of leakage from a 1/4” tube 

inserted into a threaded fitting, simply push and insert the threaded fitting further. To facilitate 

this process, use pliers and grab the tubing 1/2” from where the tube inserts into the threaded 

fitting. This will help avoid damaging the tubing which will be inserted into the threaded fitting and 

invariably prevent leakage from this location.

 

R.O. Filtration System Evaluation/Leak Prevention

Tip!

Maintaining the pre-filters of your system is key to ensure the filtration system 

sustains integrity in both water quality production and longevity of its parts and 

components. The pre-filters are the filtration systems first line of defense and thus 

paramount in promoting the maximum lifespan of the R.O. Membrane.

Note!

Alternatively, the Reverse Osmosis 5-Stage Water Filtration System can be flushed

by simultaneously allowing water to run through the system and letting the faucet 

run for 1 hour. Upon conclusion, clean, drinkable water can be enjoyed.

Содержание Reverse Osmosis 5-Stage Water Filtration System

Страница 1: ......

Страница 2: ......

Страница 3: ...y premature system degradation After installation is complete and deemed successful please read the Recommended Filter Replacement Schedule section on page 19 and keep record on your calender when you...

Страница 4: ...Adapter 9 The Auto Leak Detector Advantage 11 Re Activating the Auto Leak Detector 11 R O Filtration System Installation 12 Preparing the Discharge Water Drain Clamp 12 Prepare the R O Pressure Stora...

Страница 5: ...ation process Parts Diagram 1 Parts Diagram 2 Parts Diagram 3 Package Contents Drain Clamp ACW 2 and Gasket Water Feed Connector AB 3 4 Auto Leak Detector Screws 5 Gal Pressure Storage Water Tank Fauc...

Страница 6: ...LY Provided below are images showing the front and rear of the filtration system with filters intact We recommend to thoroughly read the installation instructions step by step in order to expeditiousl...

Страница 7: ...Microfiltration Chlorine Odor Organic Chemicals Stage 3 Carbon Pre Filter Ultrafiltration Chlorine Bad taste Odor Stage 4 RO Membrane Filter Filters dissolved minerals salts and most harmful chemical...

Страница 8: ...and determine the proper location for the unit and tank Please consider easy accessibility as it is required to periodically service the filtration system and its parts Tip Understanding installation...

Страница 9: ...Turn the sink faucet On to make sure no cold water is flowing Next use a wrench to unscrew the cold water hose from the Cold Water Valve 2 If the white gasket is not attached to the EZ Angle Stop Adap...

Страница 10: ...r end of the red PE Tubing to the R O System Out port on the Auto Leak Detector Next use the other cut red PE tubing and attach it to the Main Line In port on the Auto Leak Detector Installation Prepa...

Страница 11: ...shut down due to a leak the replacement of the used cell will be required 2 To open the housing module simply pry the upper spring trigger with your hand or use a flat screwdriver to detach pry the up...

Страница 12: ...ut the chosen spot with a 1 4 drill bit The 1 4 hole that is created into the chosen location on the drain pipe is where the black discharge line will be inserted and secured into place with the Disch...

Страница 13: ...he Discharge Water Drain Clamp in its chosen location making sure the tubing is inserted into the drain pipe by 1 4 inch as shown 5 Assemble the two pieces of the Discharge Water Drain Clamp with use...

Страница 14: ...ecurity apply 5 8 wraps of Teflon tape to the thread of the tank 2 The yellow PE tubing will now be used to connect the system to the R O Pressure Storage Water Tank Connect the yellow PE tubing into...

Страница 15: ...2 hole in the sink or counter top or utilize an existing hole should it be the appropriate size 2 Slide chrome cover plate and rubber gasket onto stem of faucet and place the faucet onto the sink wit...

Страница 16: ...ng hole should it be the appropriate size 2 Slide chrome cover plate and rubber gasket onto stem of faucet and place the faucet onto the sink with the stem going through the hole 3 Attach plastic loca...

Страница 17: ...iculates and carbon dust IMPORTANT It is advisable to turn on the cold water tap on the kitchen faucet to make sure there are no leaks anywhere within the plumbing system It is important to allow the...

Страница 18: ...Stage Water Filtration System please employ Teflon tape by way of wrapping the threads of the various threaded fittings 5 7 times This preventative measure will assist in preventing potential leaks f...

Страница 19: ...O Membrane is rated for 4 000 5 000 Gallons of purified water production A new R O Membrane will last approximately 3 4 years However it is suggested replacing the R O Membrane every 2 years for syst...

Страница 20: ...ent Filter Replacement Guide Step 1 Lift up filter approximately 30 degrees from R O filtration system Step 2 Twist filter counter clock wise and gently remove the filter from the filter housing Step...

Страница 21: ...ard from the R O filtration system approximately 45 3 Grip the filter with one hand and proceed to unscrew the filter counter clockwise in a 1 3 rotation 4 At this point the filter should detach from...

Страница 22: ...n 375 South 6th Avenue City of Industry CA 91746 Boann has the right at its discretion to replace or repair returned equipment Replaced equipment may be reconditioned Parts used in repairing or replac...

Страница 23: ......

Страница 24: ...Boann Specialized Stainless Steel Kitchen and Bath Hardware...

Отзывы: