background image

 

 

4.4 

230V SINGLE PHASE 

– With CS-7 Controller and RST-TP Thermostat. 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.  
Drawings  show  connections  inside  the  black  terminal  box  on  the  outside  of  the  heater  and  the  inside  of  the  CS-7  and  RST-TP  Thermostat 
Controllers. Other thermostats may be used BUT they must be suitable for a 3kW load. 

Do NOT use power tools to undo or do up terminal screws.

 

Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes. 

 

 

Standard Connection using CS-7 Controller and Thermostat 

Use 1.5mm² 3 Core Mains Cable (see note above). 
Use 1.5mm² 6 Core Cable to connect the heater to the CS-7 Controller (see note above). 
Use 1.5mm² 4 Core Cable to connect the CS-7 Controller to Thermostat (see note above). 
Remove  any  links 

that may be present in heater terminal box between terminals 1,2,3,4 or 5. 

 

Mains Cable (Power Supply Box) 

Connect Brown wire 

– Terminal 1 or L. 

Connect Blue wire 

– Terminal 5 or N. 

Connect Green / Yellow wire 

– Terminal E or  

 

Heater (Control Box) to CS-7 Controller Cable 

– (Colours for reference only) 

First remove the Brown link cable between L1 and 1 on CS-7 and replace with a link between L1 and 3 (shown above by dark brown wire) 

Connect Brown wire 

– Terminal 1 or L of heater and Top Terminal L2 on right DP Switch of CS-7. 

Connect Grey wire 

– Terminal 2 of heater and Centre switch Terminal 1 of CS-7. 

Connect Red wire 

– Terminal 3 of heater and Terminal 1 on Left SP Switch of CS-7. 

Connect Black wire 

– Terminal 4 of heater and Terminal 2 on Left SP Switch of CS-7. 

Connect Blue wire 

– Terminal 5 or N of heater and Top Terminal N2 on right DP Switch of CS-7. 

Connect Green / Yellow wire 

– Terminal E or 

of heater and earth connection on CS-7. 

 

CS-7 Controller to Thermostat Cable 

– (Colours for reference only) 

Connect Brown wire 

– Bottom Terminal L1 on right DP Switch of CS-7 and Terminal 3 of the Thermostat. 

Connect Grey wire 

–Terminal 1 of middle switch of CS-7 and Terminal 1 of the Thermostat. 

Connect Blue wire 

– Bottom Terminal N1 on right DP Switch on CS-7 and Terminal 4 or N of the Thermostat. 

Connect Green / Yellow wire 

– Terminal E or 

of CS-7 and earth connection of the Thermostat. 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE 

5. MAINTENANCE

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply. 

The heaters are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require no service. 
Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is especially 
important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the airways to 
ensure  completed  removal  of  any  dust. When  the  heater  is  first  turned  on  after  cleaning  an  unusual  odour  may  be  noted  this  is  due  to  the  dust 
particles which inevitably will be disturbed and will be burnt off from the heating element. 
If in any doubt always consult a qualified electrician for advice. 

 

6. AUTO CUT OUT

 

This heater is fitted with a semi-automatic safety device to prevent overheating.  The device will isolate the heating element while the fan continues 
to operate. Should this occur,  disconnect the heater from the mains supply for a minimum of 5 minutes,  check and remove any foreign materials 
around the airways. If the heater fails to operate or the safety cut out operates again, turn off the heater and contact a qualified electrician. 

 

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without 
prior notice. 

 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your  BN  Thermic  product  is  guaranteed  for  one  year  from  date  of  purchase.  We  will 

repair or replace at our discretion any part found to be defective. We cannot assume any consequential 
liability.  This  guarantee  in  no  way  prejudices  your  rights  under  common  law  and  is  offered  as  an 
addition to consumer liability rights. 

REGISTER:

 Activate your warranty by registering online at www.bnthermic.co.uk and retain this 

installation data for future reference. 

 

 

 

 

 

 

 

 

                  

SMH-30INS-v03 

This product conforms to EU Directive 2002/96/EC. 
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be  disposed of as 
domestic  waste,  but  must  be  taken  to  a  collection  centre  for  waste  electrical  and  electronic  equipment.  It  is  the  user's  responsibility  to 
dispose  of  this  appliance  through  the  appropriate  channels.  Failure  to  do  so  may  incur  penalties  established  by  laws  governing  waste 
disposal.

 

BN Thermic Ltd,  

34 Stephenson Way, 

 Crawley, RH10 1TN 

Tel: +44 (0) 1293 547361 

Email: [email protected] 

Web: www.bnthermic.co.uk 

 

Отзывы: