11. SETTING THE TIME AND DATE.

 

 

The time and date are factory set so it will not normally be necessary to do this on site. Changes between summer and 
winter time are handled automatically by the unit. 

 

1. Switch the slider to 

Time

 / 

Date

. The hour symbols will flash, use 

+

 or 

 to adjust. 

2. Press the 

Next

      button and the minute symbols will flash, use 

+

 or 

 to adjust. 

3. Press the 

Next

       button and the day date will flash, use 

+

 or 

 to adjust the day. 

4. Press the 

Next

       button and the month date will flash, use 

+

 or 

 to adjust the month. 

5. Press the 

Next

       button and the year date will flash, use 

+

 or 

 to adjust the year. 

6. Press the 

Next

       button and choose between 12hour or 24hour clock by using the 

+

 or 

 buttons. 

7. Press the 

Next

       or 

Home

      button or wait for 15 seconds to automatically confirm and return to Run mode. 

 

12. USING THE COPY FUNCTION.

 

 

The unit is provided with a copy function which allows an adjusted programme to be copied to another day or set of 
days. This avoids the necessity of re-entering a desired programme for another day or sets of days. 

N.B. This function only works in 7 Day setting. 

 

To operate the copy function 

1. Switch the slider to 

PROG

 and press the 

Home

       button. 

2. Press the 

C

 button to enter the 

COPY

 mode. 

3. The 

A

 button chooses the day you want to copy from  (day not flashing) and the 

+

/

-

 buttons choose the day you 

want to copy to (flashing). 

4. Press the 

C

 button to confirm. The screen will show 

SEr

 (to show the Copy function is set). 

 

13. BATTERY REPLACMENT.

 

 

When the low battery symbol         flashes in the LCD display, the batteries need to be replaced as soon as possible. 
The  battery  compartment  is  located  on  the  front  of  the  thermostat,  under  the  fascia  cover.  Remove  the  old  batteries 
and insert new ones. All settings including time are maintained. 
N.B. If the display ever goes blank during normal operation, the batteries need to be replaced with high quality alkaline 
cells. The date, time and factory pre-set heating times will be retained (assuming the backup battery in the back of the 
thermostat has not failed). 

 

14. RESETTING THE UNIT.

 

 

To reset the programmer to the default settings 

–  

1. Switch the slider to 

OFF

2. While holding in the 

Next      

button press and hold in the 

reset 

button

 

for approx. 3 seconds. 

3. Release the 

reset

 button while still holding in the 

Next      

button. 

4. Now release the 

Next      

button. 

 

The programmer will now reset to factory defaults with the time and date needing to be reset. 

 

SECTION 2 

– INSTALLATION AND MASTER SETTINGS 

 

15. INSTALLATION SAFETY INSTRUCTIONS. 

 

Installation Safety Instructions 

  The unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring Regulations. 

  Isolate mains supply before commencing installation. 

  Please read all instructions before proceeding. 

  Ensure that the fixed wiring connections to the mains supply is via a fuse rated at not more than 6 amps and class 

‘A’ switch having a contact separation of a minimum of 3mm in all poles. 

  The recommended cable sizes are 1.0mm² or 1.5mm². 

  No  earth  connection  is required  as  the  product  is  double  insulated  but  ensure  continuity  of  earth throughout the 

system. 

 

General Safety Instructions 

When fitting batteries, do not mix old and new batteries together. Do not use rechargeable batteries. 
This product complies with the essential requirements of the following EC Directives: 

  Electro-Magnetic Compatibility Directive 2014/30/EU 

  Low Voltage Directive 2014/35/EU 

  EC Marking Directive 93/68/EEC 

 

Please leave the user instructions with the end user where they should be kept in a safe place for further reference. 

 

Maintenance 

Always  isolate the mains  supply  before commencing  any  work, servicing  or maintenance  on the system.  And  please 
read all instructions before proceeding. 

Содержание PROSTAT2

Страница 1: ...otal Switch Rating 6 2 A 230VAC Contact Type SPDT Volt Free changeover contacts Plastic Thermoplastic flame retardant Number of Programs 4 or 6 Default 4 Number of Events per Day 4 6 Factory Pre Set P...

Страница 2: ...ot notice the effect on the temperature but you should see a slight difference in your energy bill The following options are available BUT are only of use if using the thermostat with a gas boiler 4 C...

Страница 3: ...C 4 Events Time Temp C 6 Events Time Temp C 6 Events Time Temp C 1 06 00 20 1 07 30 20 1 06 00 20 1 07 30 20 2 08 00 15 2 09 30 20 2 08 00 15 2 09 30 20 3 17 00 21 3 16 30 21 3 12 00 15 3 11 30 20 4 2...

Страница 4: ...2 Press the button to increase the set temperature in increments of 0 5 c and or press the button to decrease the set temperature in increments of 0 5 c 3 Once the desired temperature is reached and...

Страница 5: ...B If the display ever goes blank during normal operation the batteries need to be replaced with high quality alkaline cells The date time and factory pre set heating times will be retained assuming t...

Страница 6: ...the front of the thermostat underneath the fascia The Programmable Room Thermostat is now installed and will automatically start to control the room temperature according to the factory pre set progra...

Страница 7: ...gether under the fascia now press the Next button and the technical settings menu will be displayed Release all buttons 2 Press the Next button until you get to SER service interval Settings A numeric...

Страница 8: ...and allow temporary manual override temperature Up Down arrows Full Lockout 5 This mode locks all keys slider The End user cannot adjust anything Setting the Maximum Program Temperature Press the Nex...

Отзывы: