2. INTRODUCTION & SPECIFICATION

 

This heater produces a totally dry heat, no condensation, no gas, no fumes and no smell. It reaches maximum heat output within seconds of being 
turned on and has a highly polished aluminium reflector for maximum heat efficiency. It adjusts horizontally through 90° while mounted. And is 
Ideal for industrial or domestic applications, IP55 rated. 

Model 

HWP2-45B 

HWP2-45BM 

Power 

4500W 

4500W 

Input supply 

230V 50Hz 19.5A 

230V 50Hz 19.5A 

Dimensions (W x H x D) 

1440 x 125 x 125mm 

1440 x 125 x 125mm 

Mounting Bracket Stand Off 

45mm 

45mm 

Minimum Mounting Height 

1.8m 

1.8m 

 

 

3. MOUNTING INSTALLATION 

 

3.1  WALL MOUNTING (fig.1) 

 

IMPORTANT!

  The  following  points  should  be  noted: 

The  heater  should  always  have  a  minimum 
clearance  of  500mm  from  a  ceiling  and  at  least 
1000mm from any object. 

 

IMPORTANT!

  Ensure  that  the  mounting  surface  is 

capable of supporting the weight of the heater. 

 

IMPORTANT!

 

The  heater  should  be  mounted 

horizontally  where  possible  or  at  a  maximum  angle  of 
35 degrees from the horizontal. 

 

IMPORTANT! 

The  mounting  bracket  must  be 

sufficiently earthed. 

3.1.1  Remove the wall mounting bracket from the heater by 

removing the two bolts from either end of the bracket. 

3.1.2  Before drilling ensure that there are no wires or water 

pipes in the area where the heater is to be placed. 

3.1.3  Use  the  bracket  as  a  template.  Fix  the  metal  bracket 

to  the  wall  by  using  a  minimum  of  3  holes  and 
appropriate fixings (not supplied). 

3.1.4  Refit the heater back onto the bracket  
3.1.5  Adjust  the  angle  of  heater  to  direct  heat  where 

required, between 45° and 90° (see fig.1). 

3.1.6  Now tighten up the two bolts tightly. 
 

3.2  ELECTRICAL CONNECTION 

3.2.1 Please  make  sure  you  have  read  the  Safety 

instructions  and  you  are  a  suitably  qualified 
electrician before continuing. 

3.2.2 If connecting to a 20A Round Pin Industrial Plug 

a)  Connect  the  GREEN/YELLOW  earth  wire  to  the 
earth terminal ‘E’.

 

b)  Connect  the  BROWN  live  wire  to  the  live  terminal 

‘L’. 

c)  Connect  the  BLUE  neutral  wire  to  the  neutral 

terminal ‘N’. 

d) After wiring, check that there are no bare wires, that 
all wires have been correctly connected, that the cable 
outer insulation extends beyond the cable restraint and 
that the restraint is tight. 

3.2.3 Connection to a Switched Fused Spur / Isolator.

 

a) Connect the GREEN/YELLOW earth wire to the earth connection.

 

b) Connect the BROWN live wire to the live connection. 
c) Connect the BLUE 

neutral wire to the neutral connection’. 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends 
beyond the cable restraints and that the restraint is tight. 