7. COMMISSIONING 

Note: 

The infrared lamps in the heater are fragile as such it is important that they are not subjected to any unnecessary shocks or vibration and are            

not moved when in use. Wait till the heater has cooled down before moving / adjusting. 

WARNING!

 Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.

 

6.1    Perform Insulation and Earth continuity tests.

 

6.2  Switch on the heater(s) and confirm that the lamps are working.

 

6.3  Ensure  each  heater  aims  its  warmth  into  the  target  area  by  adjusting  the  heater  angle(s)  as  required,  and  then  tighten  the  bracket  bolts 

keeping the heater(s) firmly in place. 

6.4  Although the fitting can be tilted between 30º & 45º in the vertical plane,  check & ensure that the fitting remains within 10º

 

of the horizontal 

plane as the lamps are only designed for horizontal operation. 

 

6.5  The  User  /  Customer  should  be  made  aware  of  all  aspects  of  the  operation  and  safety  advice.  Keep  the  instructions  safely  for  future 

reference. 

6.6 

In unoccupied premises it is recommended that the heating system is switched off and isolated from the electrical supply.

 

 

8. MAINTENANCE

 

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply.  

 

7.1  

BN Thermic infrared quartz heaters contain no moving parts and therefore very little maintenance is required other than to ensure that there 
is  no  excessive  build-up  of  dust/dirt  on  the  reflectors  or  lamps  as  this  can  cause  overheating  and  premature  lamp  failure.  Depending  on 
installation conditions, a heater should be regularly inspected, but at least once per year. 

 

9. LAMP REPLACEMENT

 

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply. 

The lamp used in the fitting is robust and if knocks and shock vibrations are avoided, will last for around 5000 hours. 

Lamp Installation (if required) or replacement

 

1)  Undo the 4 screws on each end cover, and remove the covers. 
2)  Unscrew the 4 screws securing the guard, remove guard and slide out the end reflectors. 
3)  If replacing lamp unscrew lamp leads and remove lamp. 
4)  Carefully  remove  new  lamp  from  its  box  making  sure  you  do  not  touch  the  glass  part  of  the  lamp,  centre  lamp  to  brackets  with  leads 

pointing downwards. 

5)  Insert each end of lamp halfway under each spring clip. 
6)  Push slowly each end of lamp with equal thumb pressure fully into clips. 

N.B.

 Any inadvertent finger marks on the glass lamp can be removed using methylated spirits on a soft cloth. 

 

7)  Connect lamp leads to connector blocks. Tighten screws. 
8)  Re-assemble heater by sliding the end reflectors back, then secure the guard in position with the 4 screws. 
9)  Refit the end covers making sure no wires are trapped before tightening the screws. 
10) 

WARNING!

  Failure  to  reassemble  all  the  parts  and  use  the  guards  will  invalidate  any  remaining  guarantee  and  may  make  the  unit 

dangerous. 

 

10. SPARES

 

 

Note:

 Spare Lamps are available from your distributer.  Please quote the following Lamp codes when requesting spares  

 

Heater Model 

HN2-3000G 

 

 

Replacement Lamp Code 

RL15GF 

 

 

 

 
 
 

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without 

prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your  BN  Thermic  product  is  guaranteed  for  one  year  from  date  of  purchase.  We  will 

repair  or  replace  at  our  discretion  any  part  found  to  be  defective.  We  cannot  assume  any 
consequential  liability.  This  guarantee  in  no  way  prejudices  your  rights  under  common  law  and  is 
offered as an addition to consumer liability rights. 

REGISTER:

  Activate  your  warranty  by  registering  online  at  www.bnthermic.co.uk  and  retain  this 

installation data for future reference. 

 

 

 

 

 

 

 

 

 

   