Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes.
3. Heater Model
– 860
Model- 860 or RH60 + CS-7
Model- 860 or RH60 + CS-7 + Thermostat
4. Heater Model
– 860T
Model- 860T + CS-7
5. Heater Model
– SCHG-30T / SCHG-45T + SMH-30T / SMH-45T Series
Model
– SCHG-30T / 45T +CS-7
SMH-30T / SMH45T
Use 4mm² 3 Core Mains Cable (see
note above).
Use 1.5mm² 5 Core Cable to connect
the heater to the CS-7 Controller (see
note above).
Remove any links
that may
be present in heater control box
between terminals 1,2,3,4 or 5.
Use 2.5mm² 3 Core Mains Cable (SCHG-
45 or SMH-45T) or 1.5mm² 3 Core Mains
Cable (SCHG-30T or SMH-30T) (see
note above).
Use 2.5mm² 6 Core Cable (SCHG-45T or
SMH-45T) or 1.5mm² 6 Core Cable
(SCHG-30T or SMH-30T) to connect the
heater to the CS-7 Controller (see note
above).
Remove any links
that may be
present in heater control box between
terminals 1,2,3,4 or 5.
DO NOT REMOVE
LINK IN POWER SUPPLY BOX
Use 4mm² 3 Core Mains Cable (see note above). Use 1.5mm² 6 Core Cable to connect the heater to the CS-7 Controller (see note above).
Use 1.5mm² 4 Core Cable to connect the CS-7 Controller to Thermostat (see note above).
Remove any links
that may be present in heater control box between terminals 1,2,3,4 or 5.
Use 4mm² 3 Core Mains Cable (see
note above).
Use 1.5mm² 6 Core Cable to connect
the heater to the CS-7 Controller (see
note above).
Remove any links
that may
be present in heater control box
between terminals 1,2,3,4 or 5.