background image

 
 

BN Thermic Ltd,  

34 Stephenson Way, Three Bridges, 

 Crawley, RH10 1TN 

Tel: +44 (0) 1293 547361 

Email: [email protected] 

Web: www.bnthermic.co.uk 

 

This product conforms to EU Directive 2002/96/EC. 
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as 
domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's responsibility to 
dispose  of  this  appliance  through  the  appropriate  channels.  Failure  to  do  so  may  incur  penalties  established  by  laws  governing 
waste disposal.

 

3. MOUNTING / INSTALLATION 

 

IMPORTANT!

 Ensure that the mounting surface is capable of supporting the weight of the heater. 

 

IMPORTANT!

 

The heater should only be mounted horizontally. 

 

3.1  ELECTRICAL CONNECTION 

 

IMPORTANT!

 Ensure you have read the Safety instructions and you are a suitably qualified electrician before continuing. 

 

IMPORTANT! 

The voltage marked on the heater must correspond to the supply voltage.

 

 

IMPORTANT! 

To  comply  with  the  I.E.E.  Wiring  Regulations,  the  appliance  must  be

 

earthed;  the  supply  circuit  must  be 

adequate  for  the  input  of  the  appliance,  and  the  circuit  protected  by  a  suitable  fuse.  If  the  heater  is  to  be  connected  to  a  fixed 
electricity supply, a suitable termination must be provided adjacent to the final position of the appliance. In this instance, such 
a termination must be a double pole switch with a contact separation of at least 3mm in all poles. 

3.1.1  The terminal connection block is located under the cover on the right hand end of the heater. To access this cover unclip the 

semi-circular cover that runs the length of the heater  

3.1.2  A full length wire way is provided for use if you wish to have the cable entering from the left hand end. 
3.1.3  Connect the Earth wire normally GREEN/YELLOW to the earth terminal having the symbol -   

Connect the Live wire normally 

BROWN to the live terminal ‘L’. 

Connect the Neutral wire normally 

BLUE neutral wire to the neutral terminal ‘N’. 

3.1.4  After wiring, check that there are no bare wires, that all wires have been correctly connected and then  replace electrical cover ensuring 

screws are correctly tightened. Now replace the semi-circular cover. 

 

3.2 

PEW MOUNTING

3.2.1 The Heater must be mounted horizontally using 4 screws. 
3.2.2 Before drilling any holes ensure there are no wires or pipes in the area you are fixing the heater. 
3.2.3 After tightening the 4 screws loosen each by one half a turn to allow for expansion of the metal 

case. 

3.2.4 If mounting on church pews unless you use optional brackets they should be mounted on the back board 

under the seat in as low a position as possible and with the air inlet and outlet pointing forwards. 

3.3  FLOOR MOUNTING (using BLC-FB brackets)

 

 

3.3.1  Screw the brackets to the floor ensuring that they have been set at the correct 

pitch to line up with the mounting holes in the back of the heater.  

3.3.2 

Without  Guard

 

–  Using  the  screws  supplied  attach  the  heater  to  the  bracket 

set level and secure in place.

 

3.3.3 

With Guard

 

– Loosely attach heater to brackets. Locate guard over the top of the 

heater, then slide bottom of guard under heater. Making sure bottom of the guard 
is  against  the  back  of  the  bracket,  gently  push  heater  down  and  then  tighten 
screws holding heater to bracket. 

3.3.4  After tightening the 4 screws loosen each by one half of a turn to allow for expansion of the metal case and guard if used. 

3.4 

HANG MOUNTING (using BLC-HB brackets)

 

3.4.1 

Screw the brackets to  underneath of the Pew ensuring that they  have been set  at the correct 
pitch to line up with the mounting holes in the back of the heater

3.4.2 

Without  Guard

 

–  Using  the  screws  supplied,  screw  the  heater  to  the  brackets.  The 

screws should be tightened into the clench nuts in the bracket and not put through the 
slots. Dispose of the nuts as these are not required.

 

3.4.3 

With  Guard

 

–  Loosely  attach  heater  to  bracket  through  the  slots  using  the  screws  and  nuts 

supplied. Locate guard over the top of the heater, then slide bottom of guard between bottom of 
the heater and the bracket. Making sure bottom of the guard is against the back of the bracket, 
gently push heater down and then tighten screws holding heater to the bracket. 

3.4.4  After  tightening  the  4  screws  loosen  each  by  one  half  of  a  turn  to  allow  for  expansion  of  the 

metal case and guard if used. 

 

4. OPERATION

 

When energised the heater will provide its maximum output. Should the unit register an abnormal rise in temperature anywhere 
along  the  element  the over  temperature  safety  device  will  shut  the heater  down.  In  these circumstances  isolate  the heater  and 
ensure that there is no obstruction to the air inlet or outlet.  If the over temperature safety device operates repeatedly isolate the 
heater and consult a qualified electrician. 

 

5. MAINTENANCE

 

BN Thermic Electric Heaters are factory assembled, tested and are non-user serviceable. They are designed to operate for many years, problem 
free. Maintenance is limited to the keeping of both inlet and exhaust areas free from any accumulation of dust and other foreign materials. This is 
especially important immediately before a heating season. Any dust build-up can be loosened with a brush and a vacuum cleaner applied to the 
airways to ensure complete removal of dust materials. An unusual odour may be noted on the initial turn-on period as any dust particles may have 
been  disturbed  and  will  be  burnt  off  from  the  element.  Note:  Before  examining  or  carrying  out  any  maintenance  ensure  the  heater  has  cooled 
down and is disconnected from the mains supply.  

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts 

without prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your BN Thermic product is guaranteed for one year from date of purchase. We 

will  repair  or  replace  at  our  discretion  any  part  found  to  be  defective.  We  cannot  assume  any 
consequential liability. This guarantee in no way prejudices your rights under common law and is 
offered as an addition to consumer liability rights. 

REGISTER:

 Activate your warranty by registering online at www.bnthermic.co.uk and retain this 

installation data for future reference. 

 

BLCINS-v04 

Отзывы: