![BN Products DBS-16H Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/bn-products/dbs-16h/dbs-16h_operating-safety-instructions-manual_2781135004.webp)
Products that make money, save money and add value to your bottom line
be connected to a properly grounded outlet. If the
tool should electrically malfunction or break down,
grounding provides a low resistance path to carry elec-
tricity away from the user, reducing the risk of electric
shock. The grounding prong in the plug is connected
through the green wire inside the cord to the ground-
ing system in the tool. The green wire in the cord must
be the only wire connected to the tool’s grounding
system and must never be attached to an electrically
“live” terminal. Your tool must be plugged into an ap-
propriate outlet, properly installed and grounded in
accordance with all codes and ordinances.
Double Insulated Tools:
Tools with Two Plugs. Tool marked “Double Insulated”
do not require grounding. They have a special double
insulation system.
EXTENSION CORDS
Grounded tools require a three wire extension cord.
Double insulation tools can use either a two or three
wire extension cord. As the distance from the supply
outlet increases, you must use a heavier gauge exten-
sion cord. Using extension cords with inadequately
sized wire causes a serious drop in voltage, resulting
loss of power and possible tool damage. Refer to the
table shown to determine the required minimum wire
size.
Recommended Minimum Wire Gauge for Extension Cords
100V I 115V
(50/60Hz)
230V (50/60Hz)
Cable length
Cable size (AWG) Nominal
diameter
Up to 10m (25ft.)
16
l.Omm2
Up to 15m (50 ft.)
14
1.25mm2
Up to 30m (100ft.) 10
1.5mm2
360° Rotatable between motor and pump case