PRE-USE CHECKS:
1. WARNING: Do not expose the tool to rain or
wet conditions. Water entering a power tools will
increase the risk of electric shock.
2. Wear safety goggles, safety glasses with side shields
or a face shield when using these tools.
3. Check that the power source is appropriate to the
tool.
CARE: If voltage is too high, the motor will burn
out. If voltage is too low, insufficient power will be
generated. Never use DC current.
4. Check that cord is undamaged and that plug is not
loose.
CAUTION: Cut or abraded covering could result
in a short and electric shock to operator.
5. Check and keep work area clean and enough work
space.
6. Check condition of bending roller, center roller
and roller bolts - CHECK FOR CRACKS OR
DAMAGE, LOOSEN BOLTS
7. Screw up roller bolts.
CAUTION: Using loose rollers may result in injury
to operator as well as damage to the tool.
8. Before plugging in, make sure that switch lock but-
ton is OFF.
CAUTION: If switch lock button is ON, the tool starts
as soon as it is plugged in.To disengage the switch lock
button, pull trigger-switch to allow the switch lock but-
ton pop out.
BENDING REBAR (Max.l6mm 5/8” & Tensile strength
620 N/mm2)
WARNING: RESTRICT USE TO DESIGNATE MATE-
RIALS
This tool is rated for 16mm Max. Tensile strength
620N/mm2 Rebar only. There is always a chance that
the end of material may break and shoot out, especially
if the material harder that those specified. Exceeding
designated material specifications greatly increase this
risk and will also damage the tool. Do not attempt to
use the tool for rebars harder or thicker than those
specified.
OPERATING INSTRUCTIONS
CAUTION: Check condition of center roller and bend-
ing roller. Screw up those bolts. Using loose rollers may
result in injury to operator as well as damage to the
tool.
Make sure the unit is plugged into the proper outlet
110V, 115V or 230V 50/60Hz. (Check the voltage of
your DBS-16H.)
WARM UP
In cold weather, warm up the tool for 30-60 seconds so
that the hydraulic oil reaches the proper viscosity. Pull
trigger-switch to move bending arm then release the
switch when it has reaches its full stroke and returns.
Repeat 4-5 times without rebar.
BENDING HEIGHT ADJUSTMENT
Loosen wing bolt, adjust measuring rod and tighten
the wing bolt.
STOPPER BOLT ADJUSTMENT
AND BENDING
The stopper bolt functions to maintain the rebar in the
correct position during bending and must be properly
set for each size of rebar before bending.
Check that release lever is in CLOSE positon.
Insert a rebar between bending roller and center roller.
Loosen nut, screw out the stopper bolt until it is just
touching the rebar and tighten the nut.