Diagnosis start conditions
The main start conditions are:
- Engine OFF
- Last engine downtime > 5 hours
- Last engine operating duration > 20 minutes
The leakage diagnosis is only carried out every second time the
main start conditions are fulfilled.
The main start conditions are usually fulfilled twice daily, for
example if the driver drives to work in the morning and drives
home in the evening.
Start criterion
Start condition
DME run-on
activated
Last engine downtime
> 5 hours
Duration of current driving
operation
> 20 minutes
Fuel tank level
> 15% and < 85%
Ambient temperature
> 4 ºC and < 35 ºC
Altitude above sea level
< 2500 m
AKF filling
< limit value (almost full)
Battery voltage
> 10.95 V and < 14.5 V