19
CONFIGURING BATTERY CAPACITY
The battery capacity needs to be set whenever a new battery is fitted to the
BatteryPlus35. By default, the battery capacity is set to 100AH.
Correctly configuring the battery capacity ensures that the BatteryPlus35 will
select the best charging parameters for the caravan battery in use and the
software accurately estimates battery usage including Battery Capacity and
Time Remaining.
Enter Set-Up mode and navigate to the
batCaP
menu function. Follow the
directions in Figure 10 to configure the battery capacity. The battery capacity
can be adjusted between 50 and 600AH in steps of 10AH.
Figure 10:
Configuring the battery capacity
CONFIGURING BATTERY ALARM
Configure the battery alarm and set the low battery voltage warning threshold
to trigger the Battery Low warning on the Trek3 Home screen to indicate that the
battery requires charging.
By default, the low voltage warning threshold is 11V for lead acid batteries and
12.3V for LiFePO4 batteries.
Enter Set-Up mode and navigate to the
bataLm
menu function. Follow the
directions in Figure 11 to configure the battery alarm. The battery alarm can be
adjusted between 10.0 and 14.0V in steps of 0.5V.
Figure 11:
Configuring the battery alarm