background image

9

DESCRIPTION OF PARTS

 

q

 

WARNING INDICATOR

Indicating an issue, the RVView2 will display a warning if:
•    There is a fault with one (or more) of the loads connected to the BatteryPlus35-II, 

for example, a short or overload fault.

•    BMPRO’s BC300 + CommLink has been installed and communication with the 

BC300 is lost.

w

 

POWER SOURCE INDICATOR

Displays the power source currently being utilised by the BatteryPlus35-II for charging 
the battery and powering the loads.

Figure 2: 

The power information screen on the RVView2 Monitor

Figure 3: 

RVView2 power source indicator icons

AC MAINS ONLY

SOLAR/AUX 

BLENDING

SOLAR 

SOURCE ONLY

SOLAR/MAINS 

BLENDING

AUXILIARY 

SOURCE ONLY

3

2

4

6

7

5

1

POWER INFORMATION SCREEN

Содержание RVView2

Страница 1: ...TEAMBMPRO COM OWNER S MANUAL RVView2 ...

Страница 2: ......

Страница 3: ...Inspired by the great outdoors we have created a range of rugged smart and reliable products to power your adventures Our range of battery power and RV management and control systems gives you peace of mind when you are on the road so that you can relax in even the most far flung destinations knowing you have control over your power needs To learn more about the BMPRO range of products please visi...

Страница 4: ...oduct specifications are subject to change and improvement without notice SAFETYPRECAUTIONS Please read the Safety Precautions before installing or using the RVView2 Be sure to observe all precautions without fail Failure to observe these instructions properly may result in personal damage or personal injury which depending on the circumstances may be serious and cause loss of life Designed by BMP...

Страница 5: ...5 ...

Страница 6: ...F PARTS 9 POWER INFORMATION SCREEN 9 WATER TANKS SCREEN 11 RVVIEW2 WIRING DIAGRAM 12 USING YOUR RVVIEW2 13 SERVICING 13 FAQS AND TROUBLESHOOTING 14 SPECIFICATIONS 15 COMPLIANCE 16 WARRANTY TERMS AND CONDITIONS AUSTRALIA 17 LIMITED WARRANTY TERMS AND CONDITIONS USA 18 ...

Страница 7: ...7 ...

Страница 8: ...s the time remaining before the battery completely discharges so you ll never be left on the road without battery power In addition to battery monitoring the RVView2 enables monitoring of water levels of up to four water tanks all from a sleek wall mounted back lit display With the OdysseyLink103 the RVView2 becomes part of your Odyssey system With the Odyssey system you can use BMPRO s free Odyss...

Страница 9: ...s been installed and communication with the BC300 is lost w POWER SOURCE INDICATOR Displays the power source currently being utilised by the BatteryPlus35 II for charging the battery and powering the loads Figure 2 The power information screen on the RVView2 Monitor Figure 3 RVView2 power source indicator icons AC MAINS ONLY SOLAR AUX BLENDING SOLAR SOURCE ONLY SOLAR MAINS BLENDING AUXILIARY SOURC...

Страница 10: ...the screen The backlight will automatically turn off after 30 seconds y OUTPUT CURRENT The current provided by the BatteryPlus35 II to power loads connected to the unit The RVView2 can only show current higher than 0 5A Anything lower than 0 5A will be displayed as 0 0A u INPUT CURRENT The total current drawn by the BatteryPlus35 II from its input sources to power loads connected to the BatteryPlu...

Страница 11: ...T SCREEN CHANGE BUTTON Press the backlight screen change button to turn the backlight of the RVView2 screen on To switch the screen between the water tanks screen and the power information screen press the backlight screen change button to turn the backlight on then press the button again to change the screen The backlight will automatically turn off after 30 seconds 1 2 Figure 5 The water tanks s...

Страница 12: ...12 RVVIEW2 WIRING DIAGRAM CAN BUS CAN CABLE CAN CABLE OPTIONAL EXTRAS ...

Страница 13: ... with the BatteryPlus35 II to display important information on your water tank status and 12V power system including your battery The RVView2 does not have an ON OFF button The RVView2 receives power directly from the BatteryPlus35 II through the connected data cable The RVView2 will automatically turn off if it is not receiving power from the BatteryPlus35 II A custom cable will have been supplie...

Страница 14: ... plug the BatteryPlus35 II to a power source and begin battery charging When the battery is sufficiently charged the BatteryPlus35 II will enable power to the RVView2 Why is the input output current showing as 0 0A when there is an active current The RVView2 can only display input or output figures of 0 5A or higher If the level of current is lower than 0 5A the RVView2 will display 0 0A My Batter...

Страница 15: ...displayed if BatteryPlus35 II short circuit is detected Water Monitoring Dipper or tank bungs Monitored Battery Capacity 50 600Ah Input Voltage Range 6 16V Battery Drain 22mA with backlight off Ambient Temperature 0 50 C Dimensions mm 140W x 80H x 15 5D ...

Страница 16: ...ence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception ...

Страница 17: ...17 ...

Страница 18: ...t failures or defects caused by or associated with but not limited to failure to install or maintain correctly unsuitable physical or operating environment accident acts of God hazard misuse unauthorised repair modification or alteration natural disaster corrosive environment insect or vermin infestation and failure to comply with any additional instructions supplied with the product 4 BMPRO may s...

Страница 19: ...product is found to be in proper working order or damaged as a result of any of the warranty exclusions listed above BMPRO will not be liable for any costs charges or expenses incurred in the process of returning a product to initiate a warranty claim How Long the Warranty Lasts BMPRO warrants products against defects for a period of two years commencing from the original date of purchase Claims P...

Страница 20: ...TEAM BMPRO COM POWERING YOUR ADVENTURES BMPRO sales teambmpro com 19 Henderson Rd Knoxfield VIC 3180 Australia Unit 1 821 E Windsor Ave Elkhart IN 46514 USA teambmpro com ...

Отзывы: