background image

 

 

Model: 1800US 

Product Manual 

Thank you for your purchase of the Power Badger product! 

The Power Badger was engineered to be rugged, long lasting and easy to use. We are grateful you 

have put your trust in our company and chosen to invest your hard-earned money in our product. 

 

Table of Contents: 

Page 1 (this page) 

Page 2-3: Initial plug-in, setting-up your Badger for the first time 

Page 4: Power Badger Operation and Hidden Displays 

Page 5-6: General Information 

Page 7: Power Badger Term Definitions 

Page 8: Device Map Page  

Page 9: Device Features 

Page 10: Parts List 

Содержание 1800US

Страница 1: ...ou have put your trust in our company and chosen to invest your hard earned money in our product Table of Contents Page 1 this page Page 2 3 Initial plug in setting up your Badger for the first time Page 4 Power Badger Operation and Hidden Displays Page 5 6 General Information Page 7 Power Badger Term Definitions Page 8 Device Map Page Page 9 Device Features Page 10 Parts List ...

Страница 2: ... time displayed is AM time Once desired time is selected press the Set button The current time is now saved and the device prompts you to make a temperature units selection see next step 3 Select degrees Celsius C or degrees Fahrenheit F Use up down selection buttons to toggle between C and F Once the unit type you wish to use is displayed press the Set button The temperature units selection is no...

Страница 3: ... maintain after a Ready event If longer than a 9 hour maintain duration time is desired the Badger can be put permanently in Maintain Mode as discussed later in this manual To select the desired maintain after ready duration use the up down selection buttons to make your selection of 0 9 hours Once you have made your selection press the Set button and the unit will display OFF This concludes the u...

Страница 4: ... to start condition 4 Constant ON The device will supply constant power to the heater without further control in perpetuity More information on each particular mode can be found on page 7 Power Badger Term Definitions Hidden Menu Display Readouts The hidden readouts are only accessible when the device is in the Constant ON mode and red heater on LED indicator is illuminated Total Relay Cycles must...

Страница 5: ...tions The internal battery is a standard CR2032 button cell readily available at most battery retailers To replace the internal memory retention battery 1 Unplug the Power Badger from 120v Power 2 Remove the 6 Phillips head screws that retain the back cover 3 Remove the back cover 4 On the battery holder carefully lift the top battery retaining tab slightly away from the battery and slide the batt...

Страница 6: ...ng the front of the vehicle near the wall of a building or other vertical surface higher than the grille can help maintain engine heat Heaters Type The Power Badger Model 1800US is designed to power up to 1800 watts of resistive type load such as Engine block heaters Battery blankets pads Oil fuel and Oil pan mounted heaters These heaters must be suited to their application and sized properly for ...

Страница 7: ... the ready time so in this example of 3HR selected the engine would be maintained in a ready to start condition until 9 00am 9 hours is the maximum amount of time the unit can be set to maintain after a Ready event If longer than a 9 hour maintain duration time is desired the Badger can be put permanently in Maintain Mode as discussed later in this manual Ready Time Ready Time is a user defined se...

Страница 8: ...med Ready LED illuminated when the unit is set in timed ready mode Display shows the user set start ready time the time the device will have the engine ready to start 7 Maintain Ready LED illuminated when the unit is set in maintain ready mode Display shows current temperature 8 Digital display 9 Heater on LED Illuminated whenever power is being supplied to the output cord 10 Up select button used...

Страница 9: ... special low temperature poly blend plastic with fiber additive engineered to be rugged in extreme low temperatures The enclosure also features reinforced feet cast into the mold that allows the bottom of the unit to stand off the ground slightly helping to reduce water intrusion These feet also have holes cast through them to allow permanent mounting of the unit on a wall or a vehicle 8 Rear Cove...

Страница 10: ...7 Input power cord 120v male 1 PB1008 Output power cord 120v female 1 PB1009 Thermistor temperature sensor 1 PB1010 Input output cord strainer M20 black 2 PB1011 Thermistor cord strainer M16 grey 1 PB1018 Bottom back cover stainless mounting screw 6 PB1019 Bottom back cover to enclosure molded gasket 1 PB1021 Front membrane face stainless nails 4 Bostic Motors Inc 2017 all rights reserved 157 N Ma...

Страница 11: ...tory NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY THE LIMITED WARRANTY CONTAINED HEREIN DOES NOT EXTEND TO INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF A BREACH OF THIS WARRANTY To obtain performance of this limited warranty the alleged defective product must be returned together with reasonable proof of purc...

Отзывы: