background image

Install “Magnetic Brackets”

One magnet bracket MUST be installed at each end of your gate, attached to 

your rack.  Supplied is a high bracket and a low bracket, when installed they 

are designed to trigger the internal magnetic limit switch.  This will stop the 

gate cycle BEFORE making contact with the physical gate stops.
The best way to install the ‘magnetic brackets’ is to close the gate to hit the 

stop, slide back open 50mm, now slide the 

LOW

 magnet bracket along the 

racking 

until

 you see 

‘L

6

’ 

light up on the main control board, then adjust 

magnet on bracket and secure.  To install 

HIGH

 magnet, open gate full and 

pull back 50mm, now slide the 

HIGH 

magnet bracket along the racking till 

you see 

‘L

7

’ 

light up on the main control board, then adjust magnet on 

bracket and secure.

Check that both fully open and fully closed ‘magnetic brackets’ are in place on 

the gear rack and are functioning correctly.  Check both fully open and fully 

closed physical stops are securely in place. 

Closing

 

direction

 

Closing

 

direction

K3

L1 L2

L3

L4 L5 L6 L7

LED9

LED8

F

FORCE TORQUE

STUDY

wireless receiver

SLOW THRUST

HIGH

 magnet 

end

HIGH

 magnet 

end

LOW

 magnet 

end

L6 & L7 LEDs

5/1

1

Содержание LW550

Страница 1: ...Sliding Gate Operator User s Manual WARNING THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN...

Страница 2: ...perating 2 Keep children away from the gate and the remote control 3 Do no adjust the setting of the control panel unless you understand what you are doing 4 Learn the use of the the emergency overrid...

Страница 3: ...00mm from your wall post and approx 220mm in from the corner of the wall post The motor mounting plate is 170mm deep x 270mm wide Position the motor mounting plate side nearest to the gate approx 150...

Страница 4: ...he standard wheel that raises the gate to approx 50mm from the ground you can use high mounting blocks to lift the motor Position these spacers under the left and right sides of the motor and fasten t...

Страница 5: ...here wheels may be contacted as this will increase gate moving resistance dramatically We strongly recommend you leave your gear rack over hanging approx 100mm until after you have fitted your magnet...

Страница 6: ...il you see L6 light up on the main control board then adjust magnet on bracket and secure To install HIGH magnet open gate full and pull back 50mm now slide the HIGH magnet bracket along the racking t...

Страница 7: ...function Turn clockwise to increase force to desired setting TORQUE Adjust motor s power clockwise is bigger Have the gate in the closed position and lock in clutch give the gate a push to make sure...

Страница 8: ...ng as this will erase wipe all remotes tuned Note only 30 remotes will tune into the on board receiver Erase all remotes Hold the Study button down for 5 seconds now all remotes will be erased Remote...

Страница 9: ...s Using telecom wire Important Note Terminals for eye beams are found in the bottom left corner of the main control board To install IR beams you will need power to both IR beams Connect one IR beam t...

Страница 10: ...functioning if fitted 3 Can t locate accurately Distance of the magnetic bracket Internal Magnet is damaged Adjust position of magnet bracket Change internal magnet 4 Clutch can t work Operating handl...

Страница 11: ...ubstitute for a poorly functioning gate Warranty 1 12 months warranty from date of purchase warranty does not cover incorrect installation or damage by fusion and other insects 2 Warranty replacement...

Страница 12: ...ch input terminal Closing direction Common terminal Limist switch input terminal Open direction 15V 100mA max Power output Common terminal Infrared safety electric eye Closing direction input terminal...