bmcm PCI-PIO Скачать руководство пользователя страница 6

PCI-PIO 

Seite 6 

3.1.4

 

Connecting a Counter /  
Incremental Encoder 

The connection of "Signal A", "Signal B" and 
"Reset" is possible at any digital line.  

Make  sure  to  configure  the  relating  digital 

lines  as  input  and  to  assign  them  to  the 

counter. 

 

 

 

3.2

 

Interfacing Examples for Digital Outputs 

Serial resistors in the output lines limit the current and protect the hardware from being destroyed. 

3.2.1

 

Connecting an LED 

Only  so-called  low-current  LEDs  can  be 
used,  because  they  already  work  with 
1mA current. 
Please  also  observe  the  total  current 
listed  in  the technical  data  (see  chapter 
0). 

 

3.2.2

 

Connecting a Relay 

A  connected  relay  is  ideal  to  switch 
higher currents. Since the field coil of the 
relay  requires  a  higher  current  than 
provided by the measurement system at 
one line, a transistor is connected ahead.  

Relay  cards  featuring  8  outputs  are 

available at bmcm. 

 

 

Содержание PCI-PIO

Страница 1: ...ncoder to the zero position the use of an external counter reset is supported PCI Well Fitted in the PC The PCI PIO is installed in a free PCI slot and is supplied by the PC all this without annoying...

Страница 2: ...d is provided via the PCI bus If required additional software components can be installed as described in step 3 To avoid damages to the card and the PC turn off the PC before mounting the PCI PIO 3a...

Страница 3: ...B 7 4 A 7 14 B 8 23 A 8 33 B 9 5 A 9 15 B 10 24 A 10 34 B 11 6 A 11 16 B 12 25 A 12 35 B 13 7 A 13 17 B 14 26 A 14 36 B 15 8 A 15 18 B 16 27 A 16 37 The digital inputs and outputs are protected by se...

Страница 4: ...er reset is connected the counter can be reset at any time In comparison to a counter the quadrature decoder considers the counting direction by decoding a second phase shifted signal To activate the...

Страница 5: ...regard please also see application examples of the optocoupler you use Optocoupler cards featuring 8 inputs are available at bmcm 3 1 2 Connecting a Push Button Switch Please make sure to use a push...

Страница 6: ...e current and protect the hardware from being destroyed 3 2 1 Connecting an LED Only so called low current LEDs can be used because they already work with 1mA current Please also observe the total cur...

Страница 7: ...open inputs if necessary The device must not be used for safety relevant tasks With the use of the product the customer becomes manufacturer by law and is therefore fully responsible for the proper in...

Страница 8: ...EEE compliant WEEE Reg No DE75472248 Max permissible potentials 60V DC acc to VDE max 1kV ESD on the lines Temperature ranges operating temp 25 C 50 C storage temp 25 C 70 C Relative humidity 0 90 not...