bmcm PCI-PIO Скачать руководство пользователя страница 7

PCI-PIO 

Seite 7 

4

 

Important Notes for Using the PCI-PIO 

 

The device is only suitable for extra-low voltages - please observe the relevant regulations! Only use the card 
with PC housing closed. ESD voltages at open lines may cause malfunction. 

 

Only use non-solvent detergents for cleaning. The product is designed to be maintenance-free. 

 

Signal cables are connected at the 37-pin D-Sub female connector 

 preferably use shielded cables. For best 

possible interference suppression, connect shield at one end only. Close open inputs if necessary. 

 

The device must not be used for safety-relevant tasks. With the use of the product, the customer becomes 
manufacturer by law and is therefore fully responsible for the proper installation and use of the product. In the 
case  of  improper  use  and/or  unauthorized  interference,  our  warranty  ceases  and  any  warranty  claim  is 
excluded. 

 

In case of overload, interrupt the power supply (turn off PC) so that the multifuse on the board is regenerated. 
The fuse will be ready for use after app. 1 min. 

 

Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly 
disposed according to the WEEE directive or can be returned to bmcm at your own expense. 

 

 

 

Содержание PCI-PIO

Страница 1: ...ncoder to the zero position the use of an external counter reset is supported PCI Well Fitted in the PC The PCI PIO is installed in a free PCI slot and is supplied by the PC all this without annoying...

Страница 2: ...d is provided via the PCI bus If required additional software components can be installed as described in step 3 To avoid damages to the card and the PC turn off the PC before mounting the PCI PIO 3a...

Страница 3: ...B 7 4 A 7 14 B 8 23 A 8 33 B 9 5 A 9 15 B 10 24 A 10 34 B 11 6 A 11 16 B 12 25 A 12 35 B 13 7 A 13 17 B 14 26 A 14 36 B 15 8 A 15 18 B 16 27 A 16 37 The digital inputs and outputs are protected by se...

Страница 4: ...er reset is connected the counter can be reset at any time In comparison to a counter the quadrature decoder considers the counting direction by decoding a second phase shifted signal To activate the...

Страница 5: ...regard please also see application examples of the optocoupler you use Optocoupler cards featuring 8 inputs are available at bmcm 3 1 2 Connecting a Push Button Switch Please make sure to use a push...

Страница 6: ...e current and protect the hardware from being destroyed 3 2 1 Connecting an LED Only so called low current LEDs can be used because they already work with 1mA current Please also observe the total cur...

Страница 7: ...open inputs if necessary The device must not be used for safety relevant tasks With the use of the product the customer becomes manufacturer by law and is therefore fully responsible for the proper in...

Страница 8: ...EEE compliant WEEE Reg No DE75472248 Max permissible potentials 60V DC acc to VDE max 1kV ESD on the lines Temperature ranges operating temp 25 C 50 C storage temp 25 C 70 C Relative humidity 0 90 not...

Отзывы: