Precautions and general recommendations

This appliance is intended to be used in household and similar 
applications such. Appliance for internal use only. Place the unit 
away from water jets.
Always connect the water cooler to a water main that supplies 
drinking water only.
Before each installation, the unit must be sanitized by an 
authorized technician.
After installation, ensure that the unit is not resting on the power 
cable.
Check that the unit is level and that it is resting on a floor with 
sufficient load-bearing capacity, in an environment that is suitable for its dimensions and its use.
Before any maintenance or cleaning operation is carried out, remove the plug from the socket or 
disconnect the power supply.
Ensure that the product is not sited close to sources of heat.
To guarantee adequate ventilation, leave at least 10 cm of space around the unit.
Install the product in a clean, dry, well-ventilated environment. The product is designed to 
function in environments with a temperature range of between 5°C and 32°C - Climate Class N.
Take care not to damage the cooling fluid circuit: it is filled with R290, which is a highly flammable 
gas.  It is essential to ensure that the tubes of the refrigerant circuit are not damaged. 
Ensure that it is possible to disconnect the power supply either by removing the plug or via a two-
pole circuit-breaker, with an opening distance of the contacts that allows complete disconnection 
in the conditions of overvoltage category III, placed upstream of the plug.
Check that the voltage shown on the serial number plate corresponds to the voltage being 
supplied at the installation site.
The unit must not be cleaned with a water jet. Do not position other electrical equipment in the 
immediate vicinity of the water cooler.
Turn off the main water inlet tap if the unit is not to be used for a long period. 
Keep the areas surrounding the unit dry to avoid the risk of people slipping.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent 

or similarly qualified person in order to avoid a hazard. Do not use extension leads or 

adapters.
This appliance is intended to be used by persons (including children aged from 8 years) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, 

provided that they have been given supervision or instruction concerning use of the 

appliance by a person responsible for their safety. Children should be supervised to ensure 

that they do not play with the appliance. The appliance is only to be installed in locations 

where it can be overseen by trained personnel.
The Appliance shall be protected by a ground-fault circuit interrupter.
This equipment is to be installed in compliance with the local plumbing codes. Water 

pipe connections and fixtures directly connected to a potable water supply shall be sized, 

installed, and maintained in accordance with federal, state, and local codes.

This publication is based on information available when approved for printing. Continuing design 
refinements could cause changes that may not be included in this publication.

Содержание COOL1

Страница 1: ...1 6 0 4 5 5 1 7 0 5 EN Before Install or use the product read to the precautions and general recommendations inside COOL1 Us e M a i n t e n a n c e M a n u a l...

Страница 2: ......

Страница 3: ...ns of overvoltage category III placed upstream of the plug Check that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site The unit must not...

Страница 4: ...RTIFIED 7 ASSOCIATIONS 8 INTERNATIONAL AWARDS 8 DESCRIPTION OF THE UNIT 9 KEYPAD DESCRIPTION 12 TECHNICAL FEATURES 13 INSTALLATION 16 INSTALLATION OF THE CO2 CYLINDER FIZZ MODEL 20 HANDLING THE GAS CY...

Страница 5: ...URA product We have designed and manufactured this product with great care to ensure that it will dispense water of the highest quality In order to get the most out of your water cooler please read th...

Страница 6: ...t should not be treated as domestic waste but should be taken to a dedicated recycling centre for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more in...

Страница 7: ...terial Decrees 174 of 06 04 2004 and 25 of 07 02 2012 Electrical safety This water cooler is designed manufactured and marketed in compliance with the safety objectives of the Machinery Directive 2006...

Страница 8: ...RDS 2015 ROME 2014 BEST PROMOTION OF HEALTH AND HYDRATION EUROPEAN AQUA AWARDS 2014 BUDAPEST 2013 BEST PRODUCT INNOVATION EUROPEAN AQUA AWARDS 2013 BERLIN 2012 BEST ENVIRONMENTALLY FRIENDLY PRACTICE E...

Страница 9: ...nd and main body in stainless steel High insulation ice bank with a high output of cold still and sparkling water available in versions 150 lt hr and 80 lt hr 3 dispensing options FIZZ model cold wate...

Страница 10: ...3 4 5 6 7 Cold sparkling water dispensing nozzle detachable Room temperature water dispensing nozzle detachable Drip tray with grid Cold water dispensing nozzle detachable Dispensing buttons Front pa...

Страница 11: ...11 Rear view 3 2 1 6 5 4 1 4 5 6 3 Ice bank overflow waste pipe 8mm Power button Adjustable thermostat Drinkable water inlet pipe joint 8mm Drip tray waste pipe 40mm 2 IEC power cord plug...

Страница 12: ...utton P 5 COLD WATER PRESSURE ACTIVATED DISPENSING button P 7 The water is dispensed while pressure is being applied to the button SPARKLING WATER START STOP DISPENSING button P 2 ROOM TEMPERATURE WAT...

Страница 13: ...13 Technical Features Technical Data Plate 17 Year of manufacture 04 Month of manufacture 03030 Serial number mod Cool1...

Страница 14: ...317mm 40 224in 1022mm 16 449in 418mm 56 673in 1440mm 18 866in 479mm 2 926in 74mm 4 598in 117mm 11 685in 297mm 16 864in 428mm Water Inlet 27 547in 700mm Drip Tray Drainage 31 418in 798mm Ice Bank Drai...

Страница 15: ...carbonation pump Power supply Single phase 230V 50Hz Power consumption 920 W 4 A 300W 1 3 A Compressor power 1 3 HP 1 3 HP Cooling Forced ventilation Refrigerant gas Natural gas HC R290 Ambient cooli...

Страница 16: ...transported in a horizontal or inclined position a wait of 8 hours is needed before turning it on so that the refrigeration circuit can function perfectly Ensure that a qualified technician connects i...

Страница 17: ...nd the unit to allow for aeration SANITIZE the machine as described in the paragraph on page 24 Filling the ice bank Open the front panel using the key supplied Pour drinking water into the ice bank u...

Страница 18: ...on return valve Connect waste pipes 3 and 1 to a waste water manifold Once the pipes are attached turn on the tap Ensure there are no leaks Before drinking the water from the system perform a thorough...

Страница 19: ...FIZZ models the pump for filling the carbonator with water is also activated Press the Sparkling Water button in order to release any air in the circuit and to allow the pump to fill the carbonator w...

Страница 20: ...in these dimensions The unit is equipped with a tear tape for the safety fixing of the cylinder To increase or decrease the level of carbonation of the water you need to adjust the screw 1 Turning it...

Страница 21: ...r cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise their integrity and resistance The cylinders must not be lifted by the cap or dra...

Страница 22: ...ontaminants such as asbestos fibres and micro organisms such as Cryptosporidium and Giardia It protects gaskets pumps tubes and valves against blockages corrosion and abrasions Approved by the Italian...

Страница 23: ...bar Maximum pressure 9 bar Radiation 30000 Ws cm Green LED ON lamp lit Maximum capacity of the lamp 9000 h max 12 months The UV sterilizer is made entirely in Italy and complies with Italian and Europ...

Страница 24: ...carried out by the BLUPURA Reseller or by qualified technical personnel who have completed specific training courses on hygiene and sanitization To sanitize the unit we recommend the use of hydrogen p...

Страница 25: ...SPRAY cod 190109 and rinse after use DO NOT USE alcohol or solvent based products or excessively acidic solvents that can ruin the surface of the steel Cleaning the drip tray When it is necessary to...

Страница 26: ...26 Service history Installation Technician Date Notes Signature Maintenance Technician Date Notes Signature...

Страница 27: ...ing defects The warranty does not include normal wear and tear to the components or any damage caused to the components due to negligent or improper use or due to a non standard installation The warra...

Страница 28: ...ura srl Registered office Via F lli Brancondi 56 60025 Loreto AN Italy Headquarters Via Erideo Marinucci 2 4 62019 Recanati MC Italy Tel 39 071 9710080 Fax 39 071 9710084 info blupura com www blupura...

Отзывы: