36
EN
If the problem is:
And this condition exists:
Then do this:
Carbon build-up
Dirt or film on reflector
and emitter
Clean burner.
Flash back (flame inside
burner)
Burner ports are blocked.
Switch OFF the appliance.
Close LPG cylinder valve.
Wait 2 minutes, following
the ignition procedure.
Ignite burner. If problem
continuous, switch-off.
Contact your dealer.
Thick black smoke
Blockage in burner
Turn control knob to
"OFF", let it cool to room
temperature and remove
blockage and clean burner
inside and outside.