44
V1.0
SmartBus P900-S32 Series USER MANUAL
1. Ensure that the system is in USER PROGRAMMING mode.
2. Press [▼] to scroll down to
Date
.
3. Press
[#]
to select
Date
.
4. Enter the [
DATE]
in DDMMYY format. Example 22
nd
February 2010 is 220210.
5. Press
[#]
key to confirm the date.
6. Press
[
]
to exit user programming mode.
Users are advised to test the system as frequent as possible. System must be tested at least
once every 3 months. If the system is not functioning accordingly, please contact your system
installer for technical assistance.
1. Walk Test allows on-site testing of each zone of the system.
2. Press
[MODE] + [1] + [#]
or from MENU, i.e,
(Menu
System Test
WalkTest).
3. Siren will trigger for 2 seconds and keypad buzzer will sound briefly if any zone is violated
during walk test mode.
4. If siren and keypad do not sound when zone is violated, consult your system installer.
5. To exit Walk Test, simply press
[#]
key.
25.19 PROGRAM SYSTEM DATE
26.0 TESTING THE SYSTEM
26.1 WALK TEST