BVC6200LM Instruction Manual v.01
- 27 -
6.2.1 DSNU
This command adjusts the uniformity of the dark signal. When it is adjusted, put the lens
cap on the lens.
Setting Procedure
1) Put the lens cap on.
2) Select ”User Set 1” or “User Set2” in the pulldown menu of ”DSNU” and click
“Load” button.
3) Click ”ADJUST” button. DSNU compensation is executed.
4) In order to save the compensation data of DSNU and click “SAVE” button.
5
)
When this compensation data is reused, select ”User Set 1” or “User Set 2” in the
pulldown menu of “DSNU” command and click ”LOAD”.
6)
In order to make ”DSNU” OFF, select ”No Adjustment” in the pulldown menu,
and click ”LOAD”. The data is reverted to the data before the adjustment is
executed.
Click
「
ADJUST
」
Select
「
User Set 1
」
or
「
User Set 2
」
Factory Default
:
Default setting
Click
「
SAVE
」
Click
「
LOAD
」
2)
3)
4)
5)
No Adjustment
:
OFF
6)