BVC6200LM Instruction Manual v.01
- 18 -
5.3.3 Trigger mode
ON
、
SHUTTER_SELECT_MODE
Exposure start timing need to be set by each channels to be aligned all channels exposure end.
The longest exposure time setting channel start exposure when External trigger has been input.
。
Each channels exposure start time are vary to output of all video at the same timing.
Exposure period
Video data
Exposure period
Video data
Exposure period
Video data
Exposure period
Video data
<R>
<G>
<B>
External Trigger
(CC1 or DCIN Trigger)
E x t e r n a l t r i g g e r c y c l e
E x t e r n a l t r i g g e r c y c l e
Exposure start
Exposure end
Exposure end
Exposure end
Exposure end
<SWIR>
<
Command
>
exporsure time : exp r
exp g
exp b
exp ir
trigger mode : trgmode 1
trigger input CC1 : trgsource 1
DCIN : trgsource 2
Trigger polarity active Low : trgpolarity 0
active High: trgpolarity 1