BVC6100LM Instruction Manual v.01
- 50 -
shadingadjust
Execute the Shading compensation
shadingsave␣[PRAM①]
[PRAM①] setting number
1: Default
2: User Set 1
3: User Set 2
Save the adjusting value for the Shading
compensation in [PRAM
①
]
2~3: for user, 1: for Factory setting
Access limit is set by control tool side.
No limit of 1~3 at camera side.
DSNU
dsnu
Acquire the current Shading setting number to
be set
dsnu␣[PRAM①]
[PRAM①] setting number
0:No Adjustment
1:Default
2:User Set 1
3:User Set 2
Set the DSNU setting by [PRAM
①
]
dsnuadjust
Execute the DSNU compensation
dsnusave␣[PRAM①]
[PRAM①] setting number
1: Default
2: User Set 1
3: User Set 2
Save the adjusting value for the shading
compensation in [PRAM
①
]
2~3: for user, 1: for Factory setting
Access limit is set by control tool side.
No limit of 1~3 at camera side.
LUT
lutmode
Acquire the current setting LUT number
lutmode␣[PRAM①]
[PRAM
①
] Setting number
0: LUT disable
1
:
LUT enable
Set the LUT setting by [PARM
①
]
lut␣[ChNum]␣[PRAM①]
␣[PRAM②]
[ChNum] R
、
G
、
B
、
IR
[PRAM①]
table value(input)
0~4095
[PRAM②]
table value(output)
0~4095
3 parameters need to be set for LUT data
writing.
[ChNum]:
[PRAM①]: input value for LUT table
[PRAM ② ]:Output value setting against
LUT input value which
set the one of 4ch
is
set at [PRAM②]
lut ␣ [PRAM ① ] ␣ [PRAM
②]
[PRAM①] R
、
G
、
B
、
IR
[PRAM②]
Table value(input)
)
0
~
4095
Ch setting and LUT table input need to be
set for LUT data readout.
[PRAM①]:
set the one of 4ch
[PRAM②]:LUT table input value
lutsave
Save the LUT table data
lutdownload
Upload the LUT table data from PC to the
camera (file format csv)
Aberration
abemode
Acquire the ON or OFF information currently
set.
abemode␣[PRAM①]
[PRAM①]
abberation ON/OFF
0:OFF
1:ON
Set the aberration mode “ON” or “OFF”
abeload
Acquire the load number of the current
aberration compensation.
abeload␣[PRAM①]
[PRAM
①
]
Aberration
compensation load number0
~
5
Load the aberration compensation load
number [PARAM
①
]
abesave␣[PRAM①]
[PRAM
①
]
Aberration
compensation save number0
~
5
Save the aberration compensation data of the
load number [PARAM
①
]
abeadjust
Adjust
the
aberration
compensation
automatically
abedefault
Revert the aberration compensation data to
the default (Initialization, Value=0)
abeleftposi␣[ChNum]
[ChNum] sensor ch
R、G、B、IR