Hardware User Manual - Argos3D – P100
Last change: 22 August 2013
Version
1.5
Pin No.
Signal Name
Power Domain
Type
Description
1
HARDWARE_TRIGGER
1)
3V
I
Camera trigger input
2
EXT.MOD_N
3V
DP
Modulation signal output-
3
EXT.MOD_P
3V
DP
Modulation signal
4
SGND
-
PWR
Ground
Table 7-7: Modulation Light Interface
7.5.1.1
Timing diagram of the Hardware-Trigger signal
t
LAT
t
PH
t
PL
HW trigger edge
Illumination modulation signal
Figure 7-4: Timing diagram of the hardware trigger signal
Timing value Description
Min
Typical
Max
Unit
t
PL
Pulse Low Time before Trigger
50
ns
t
PH
Pulse High Time
50
ns
t
LAT
Trigger Edge to Frame Capture Latency TBD
60
TBD
µs
Table 7-8: Timing specification for the hardware trigger signal
7.5.2
USB Micro B Connector (b)
A standard micro USB B Connector is used for connecting the Argos
3D
- P100 to a host computer.
7.5.3
Power connector (c)
Connector Type: 2.1mm ID / 5.5mm OD
Polarity:
Note
Only use the provided power supply.
© Bluetechnix 2013