7.4.2
Integration Time vs. Frame-rate
The following table shows recommended frame-rate integration time combinations depending on the
environment temperature.
Figure 7-3: Integration Time vs Frame-rate
The limit of the frame-rate and integration time combinations is given by the Frame-rate Integration Time Product (FITP) which
is calculated as follow:
𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝐹
=
𝑡𝑡
𝐼𝐼𝐼𝐼𝐼𝐼
[
𝑚𝑚𝑚𝑚
]
∙ 𝑓𝑓𝑓𝑓𝑚𝑚
�
1
𝑠𝑠
� ∙
4
.
The maximum possible FITP at 25°C for the Argos-P100 is 550!
Caution
Be careful to not stress the device beyond the limits, otherwise you may damage the device.
7.5
Connector Description
7.5.1
Modulation Light Interface (a)
Mating Connector Type:
MQ172X-4SA-CV
The Modulation Light Interface provides the modulation signal for an external illumination module (differential
LVDS, 3V).
Caution
Overvoltage on the Modulation Light Interface will destroy the Argos
3D
- P100.
Pin No.
Signal Name
Power Domain
Type
Description
© Bluetechnix 2013