Battery LED indications
#
OPERATING MODE
TIMEOUT
LED INDICATION
1
BATTERY DETECTION
Battery detected while the other on
the same pair is already charging
BATTERY WAITING:
GREEN: 1sec ON/1sec OFF
2 BATTERY NOT ALLOWED
10Kohm < ID resistor < 60Kohm
BATTERY NOT ALLOWED:
GREEN: 500ms/RED: 500ms
3
BATTERY EVALUATION
i)
Total pack voltage < 8000mV
ii)
I < 10mA
If the charging does not rise within
30sec, the battery does not accept
charge
iii) Single cell voltages < 2800mV
10mA < I < 50mA
iv) Single cell voltages > 2800mV
Total pack voltage < 13000mV
50mA < I < 300mA
3600sec
1200sec
VOLTAGE TOO LOW:
RED flashing
500ms ON/500ms OFF
BATTERY FAILURE:
Steady RED
PRECHARGE-1:
ORANGE flashing
500ms ON/500ms OFF
PRECHARGE-2:
ORANGE flashing
250ms ON/250ms OFF
4 CONSTANT CURRENT MODE
13000mV < V < 16750, I = max 4A
18000sec
CC-MODE:
Steady ORANGE
5
CONSTANT VOLTAGE MODE
V >16750mV
150mA < I < 4000mA
10800sec
CV-MODE:
ORANGE 500ms/
GREEN 500ms
6
FULL CHARGE
V
≅
16800mV
I
≅
150mA
FULL CHARGE:
Steady GREEN
7
OTHER INDICATIONS
In the case of premature charge
termination, the charger retries to
charge the battery every 30 seconds.
If after 10 minutes, there is still no
response, the indication is changed
into ‘BATTERY FAILURE’
PREMATURE CHARGE
TERMINATION:
RED: 250ms ON/100ms OFF
/250ms ON /1sec OFF
(2 1 pause)
BATTERY FAILURE: