SECTION 3
32
BLUE
LINE VORTEX 7000HHP
25 hours.
If the hoses show any signs of damage
or impending rupture, replace the hoses.
!
NEVER attempt to repair high-pressure
solution hoses. Repairing high-pressure solution
hoses may result in severe burns and serious
injury, damage to property or fatality.
All high-pressure solution hoses must be rated
for 3000 PSI at 300 deg. F. Thermoplastic hoses
do not meet this requirement and should not be
used. Severe burns and serious injury, damage
to property or fatality may result if the hoses do
not meet these requirements.
7. GENERAL SERVICE
ADJUSTMENTS
!
DO NOT attempt to service this unit while it is
running. High speed parts as well as high
temperature components may result in severe
injury, severed limbs, or fatality.
VACUUM RELIEF VALVE
With the unit running at full RPM, block off the
airflow at the vacuum inlet ports and read the
vacuum gauge. If adjustment is required, disengage
the PTO (power take off) unit, and adjust the
tension with the locking nut on the vacuum relief
valve. Reengage the PTO unit and read the vacuum
gauge. Repeat this process until the vacuum relief
valve opens at 15” to 17” Hg.
VACUUM PUMP DRIVE BELTS
The
VORTEX 7000HHP
®
mobile truck unit is
equipped with an adjustable belt tensioning
system. Check belts for proper tension
(approximately 1/2” deflection) and wear.
Adjust or replace as needed.
Proper alignment of vacuum pump pulley, belt
tensioner pulley and PTO drive pulley should be
checked and adjusted in the first 25 hours of
operation, and whenever belts are removed or
replaced.
Place a straight edge between vacuum pump pulley
and belt tensioner pulley, and ensure full contact of
straight edge on both the right and left side of each
pulley. Repeat procedure on the PTO and belt
tensioner pulley. Adjust vacuum pump and or PTO
drive as needed and ensure all bolts are properly
tightened.
WATER PUMP DRIVE BELT
To tighten the water pump belt:
1. Loosen the bolts, which hold the water pump
and oil pump to the frame base.
2. Adjust the position of the belt tensioning
adjusting bolt until the proper belt tension is
Содержание VORTEX 7000HHP
Страница 4: ......
Страница 13: ...SECTION 2 BLUELINE VORTEX 7000HHP 9 ...
Страница 16: ...SECTION 2 12 BLUELINE VORTEX 7000HHP Water System 3 1 ...
Страница 20: ...SECTION 2 16 BLUELINE VORTEX 7000HHP ...
Страница 31: ...SECTION 3 BLUELINE VORTEX 7000HHP 27 ...
Страница 73: ...SECTION 4 BLUELINE VORTEX 7000HHP 69 ...
Страница 79: ...SECTION 4 BLUELINE VORTEX 7000HHP 75 68 102 KIT VORTEX STORAGE RACKS 68 013 ASSY VAN STORAGE UNIT SS ...
Страница 80: ...SECTION 4 76 BLUELINE VORTEX 7000HHP 68 014 ASSY SINGLE 5 GAL JUG HOLDER 68 015 ASSY FURN BLOCK HOLDER SS ...
Страница 81: ...SECTION 4 BLUELINE VORTEX 7000HHP 77 68 016 RACK DOUBLE CHEMICAL 68 018 ASSY 10 GAL CHEM RACK S S ...
Страница 82: ...SECTION 4 78 BLUELINE VORTEX 7000HHP 68 019 SPRAY BOTTLE HOLDER SS 68 022 ASSY DBL PMP UP SPRAY RK SS ...
Страница 83: ...SECTION 4 BLUELINE VORTEX 7000HHP 79 68 024 ASSY SNG PMP UP SPRAY RK SS 68 023 ASSY REEL HP SOLUTION ...
Страница 84: ...SECTION 4 80 BLUELINE VORTEX 7000HHP 68 025 ASSY HOSE REEL HIGH PROFILE 68 033 ASSY HOSE REEL H PROFILE W MTR ...
Страница 85: ...SECTION 4 BLUELINE VORTEX 7000HHP 81 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Страница 86: ...SECTION 4 82 BLUELINE VORTEX 7000HHP 68 109 ASSY KIT WATER SOFTENER VRTX ...