8. Setting of the acoustic alerts 

 

The acoustic alert can be activated by a short press of the 

L

oudspeaker-

S

ymbol-button (LS). At the same time the  

yellow ALERT-LED starts blinking. 
The existence of gases can therefore be detected in an audio-visual way. The frequency of the acoustic alert is 
thereby positively related to the increasing gas concentration. 
 
The acoustic alert (permanent beep) that is preset for a concentration of >2,000 ppm (Methane) can be altered within 
the active range of measuring. This can be done as explained in the following:   
Press the button with the loudspeaker symbol (LS) for about a second and press the CAL-button very briefly at the 
same time. 
The blinking ALARM-LED shows the active mode that can now be changed upwards or downwards by pressing the 
CAL-button and ON/OFF-button respectively. 
The current mode is thereby indicated by a glowing LED-segment. The setting can be finished by a short press of the 
LS-button. From now on the permanent alert will go off when the gas concentration exceeds the new set limit (e.g. 
500 ppm). 
 
 
 

Содержание GSP1

Страница 1: ...50394 Version 09 2006 Part No 22628 o Subject to technical changes User Manual for Gas Detector with graphical LED Indicator Read the instructions before using the instrument Consider security advice...

Страница 2: ......

Страница 3: ...Gas Detector GSP1 Function button Graphical LED Indicator Measuring unit with gas sensor Flex arm ON OFF button Button for setting alerts...

Страница 4: ......

Страница 5: ...fety instructions 1 3 Battery and device disposal 2 4 Application area 2 5 Product description 2 6 Technical data 3 7 Use 4 8 Setting of the acoustic alerts 5 9 Charging 6 10 Safety instructions 7 11...

Страница 6: ......

Страница 7: ...he device or sensors Protection of the measuring instrument Keep the instrument away from paint solvent and glue and store it in a dry place Safety measures in order to maintain product warranty The i...

Страница 8: ...an outstanding way for the use within the area of heating and gas installations The GSP1 can be used to examine gas pipelines gas meters gas tanks and other gas conducting components The GSP1 can be u...

Страница 9: ...20 50 ppm Methane Batteries NiMH Hours of use approx 24 hours Auto off 5 minutes Size device 72 x 130 x 26 mm Size flex arm 295 mm incl sensor Temperature humidity for storage 5 C 40 C 23 F to 104 F...

Страница 10: ...aces where they are assumed to be The measured concentration can be read of the graphical LED Indicator If the display has reached its highest status there is a constant beep as acoustic alert During...

Страница 11: ...f 2 000 ppm Methane can be altered within the active range of measuring This can be done as explained in the following Press the button with the loudspeaker symbol LS for about a second and press the...

Страница 12: ...tes the current battery status by a blinking LED segment During recharging the green POWER LED is blinking whereas the red LowBatt LED is glowing permanently When the battery is recharged completely b...

Страница 13: ...If the device is stored at a temperature below 0 C 32 F it should be switched on at least 10 minutes before starting to work with it The gas detector GSP1 is not explosion protected and may therefore...

Страница 14: ...struction In this case there are optical LED elements are flashing and acoustic ALARM LED blinks warnings Measuring can be started again by the ON OFF button A defect sensor is indicated by all segmen...

Страница 15: ...9 12 Notes...

Страница 16: ......

Страница 17: ......

Отзывы: