40
Shenyang Bluelight Automatic Technology Co., Ltd.
BL6-DU20PX series Integrated Door Motor Controller User Manual
Chart 6.8 F7 I/O Parameters (Cont’d)
Function
Code
Name
Setting
Range
Factory
Default
Setting
Min
Unit
Description
F708
Programmable
Relay output
Terminal
0~6
-
1
0: Invalid
1: Bypass Alarm Signal Valid, Relay Action
2: Bypass Alarm Signal Invalid, Relay Action
3: Arrival Gong Signal Valid, Relay Action
4: Arrival Gong Signal Invalid, Relay Action
5: Door Arrival to the Open limit Signal
Invalid, Relay Action
6: Door Arrival to the Close limit Signal Invalid,
Relay Action
F709
F710
Relay
output
Terminal
Stan
d
ard
Ty
p
e
0~2
0
1
0: Invalid
1: Car Light Signal Valid, Relay Action
2: Car Light Signal Invalid, Relay Action
S Ty
p
e
0~6
0
1
0: Invalid
1: Bypass Alarm Signal Valid, Relay Action
2: Bypass Alarm Signal Invalid, Relay Action
3: Arrival Gong Signal Valid, Relay Action
4: Arrival Gong Signal Invalid, Relay Action
5: Door Arrival to the Open limit Signal
Invalid, Relay Action
6: Door Arrival to the Close limit Signal
Invalid, Relay Action
F711
Terminal Filter
Time
0~99m
s
20ms
1ms
This parameter is used to set input terminals’
sensitivity. If digital input terminal is prone to
interference
and
cause
malfunction,
this
parameter should be increased to enhance the
anti-interference ability, but it will reduce the
sensitivity of the input terminal.
6.9
F8 SYLG Car Top Board Parameters
This group of parameters are used in Bluelight integrated control system. (Not available for S
type)Chart 6.9 F8 SYLG Car Top Board Parameters
Function
Code
Name
Setting
Range
Factory Default
Setting
Min
Unit
Description
F800
Basic
Software ID
Read
Only
Depends on
the product
0
Basic Software version of Car Roof Board.
F801
User ID
Read
Only
Depends on
the product
0
User ID of Car Roof Board
F802
~
F804
Logic
Software No.
0 ~ 2
Read
Only
Depend on the
product
0
Software No. of Car Top Board
composed of No. 0 & No. 1 & No. 2.