![Bluegiga IWIP3G - IWRAP - IPHONE 3G Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/bluegiga/iwip3g-iwrap-iphone-3g/iwip3g-iwrap-iphone-3g_user-manual_2777547016.webp)
16
Initial mode
Target mode
Requirements for
state transition
Command Mode
(no Bluetooth connections)
In this mode, ASCII commands
can be given to iWRAP.
Data
Mode
A connection is successfully
created by using the
CALL
command and
CONNECT
event
that indicates a successful
connection is received.
A remote device opens a
Bluetooth
connection to iWRAP.
A
RING
event that indicates a
received connection is received.
Data Mode
In this mode, all data is sent
transparently from UART
interface to
Bluetooth
connection.
Command
Mode The user switches mode by
sending an escape sequence to
iWRAP firmware or by toggling
the DTR pin.
A link is terminated (closed by
the remote device or by link
loss) and
NO CARRIER
event is
received.
Command Mode
(active connection)
In this mode, ASCII commands
can be given to iWRAP.
Data Mode
User switches the mode either by
sending the escape sequence or
command
SELECT
command.
Table 1:
iWRAP modes transitions explained
The escape sequence:
The escape sequence causes the iWRAP firmware to go to the command mode from the
data mode or vice versa. The escape sequence consists of three (3) escape characters that
are defined by
SET CONTROL ESCAPE
command. By default the escape character is ‘+’.
Do not enter any character before and/or after the escape sequence for a guard time
which is 1 second. Also send the escape characters individually, not as a string.
With default settings the escape sequence is:
< 1 second sleep> +++ < 1 second sleep>
When a successful state transition from data mode to command mode is made, iWRAP
sends a “
READY.
” event to indicate that it’s ready to receive commands.
The same escape sequence or the
SELECT
command can be used to return to data mode.
Содержание IWIP3G - IWRAP - IPHONE 3G
Страница 1: ...iWRAP3 U s e r G u i d e V e r s i o n 1 3 F r i d a y S e p t e m b e r 2 6 2 0 0 8...
Страница 31: ...31 INQUIRY 3 INQUIRY 00 18 42 f1 a5 be 5a020c INQUIRY 00 17 e4 ef f9 01 50020c INQUIRY 00 07 80 87 68 ec 200428...
Страница 33: ...33 Note IC command cancels the inquiry only if issued before the INQUIRY num_of_devices message...
Страница 116: ...116 6 18 2 Examples How to disable default escape character and configure DTR to PIO5 SET CONTROL ESCAPE 20 1...
Страница 169: ...169 9 7 RS232 Connections Diagram Figure 7 RS232 connections...
Страница 187: ...187 Example trace of file reception via OPP Figure 12 Receiving a vCard over OPP...
Страница 197: ...197 Figure 17 MSC signal directions...