background image

OPERATION USING BOTTLE GAS

1.  Never use another source of energy at the same time (mains or battery). 

2.  Operation on gas is prohibited in small closed areas, in small vehicles and in 

boats. When using the appliance in caravans and mobile homes, a well and sound 
ventilation should be provided. Vents in the wall facing the back of the fridge 
have to be provided with all other flu pipes etc to ensure sound ventilation. All 
works MUST be done by an experienced fitter. In all cases the location should be 
protected from rain and/or splashing. 

3.  The fridge doesn’t come with a flue kit, but a flue bend is provided which can be 

fitted at the top of the exhaust outlet on the back of the fridge. This flue bend is to 
assist in fitting any other parts of a suitable flue kit. All works for the fitting of a 
flue kit should be done by an experienced fitter. 

4.  The gas cylinder must be stored in a cool, dry, ventilated area and never 

in a basement or a cellar. Protect from sunlight and do not expose to high 
temperatures. 

5.  The appliance cannot operate at a pressure other than the one specified on the 

identification label at the back. It is recommended to use an appropriate pressure 
regulator. 

6.  During connection of the fridge to the gas cylinder, always stay clear of any sort of 

ignition and do not smoke. Connect in the order: gas cylinder – pressure regulator 
– appliance. Excessive twisting and bending of the flexible hose must be avoided. 
Check for leaks should be done only by means of soapy water. Never check for 
leaks using a flame. When changing the gas cylinder or disconnecting the hose, 
it is necessary to close the valve of the gas cylinder. Always replace a damaged or 
porous hose. 

7.  The gas valve knob (right) is a combination of gas control and ignition. 

Furthermore the gas valve assembly consists of an incorporated safety pilot, a 
burner with an ignition plug and a piezo igniter. The safety pilot automatically 
maintains the gas supply as long as it remains lit. It automatically shuts off the 
supply of gas if the flame goes out. 

Содержание ACTIVE XC-43G

Страница 1: ...For use with BLUEFIN ACTIVE Absorption Refrigerator 12V 230V Gas Model XC 43G FA50G XC 62GAS FA60G...

Страница 2: ......

Страница 3: ...re with your device please read this manual carefully before operation The operational safety and function of the device can only be guaranteed if the general safety and accident preventionregulations...

Страница 4: ...t play with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 This appliance is intended for use as a cool box using with three ways source energy The thr...

Страница 5: ...farm houses and by clients in hotels motels and other residential type environments bed and breakfast type environments catering and similar non retail applications 13 For appliances have compartments...

Страница 6: ...e unit and the wall must be at least 10 cm The minimum distance to be observed on the sides shall be at least 5 cm Avoid placing the appliance in direct sunlight or near any source of heat Do not cove...

Страница 7: ...0V thermostat knob left clockwise to the position max After about one hour the effects of the cooling process become visible frost on the inside evaporator 4 The thermostat enables the temperature of...

Страница 8: ...t the engine 4 When using a battery as a power source there is no thermostatically temperature controller i e you cannot increase or decrease the temperature inside the fridge The cooling performance...

Страница 9: ...never in a basement or a cellar Protect from sunlight and do not expose to high temperatures 5 The appliance cannot operate at a pressure other than the one specified on the identification label at t...

Страница 10: ...the system which has to be forced out It is necessary to check that the pilot is lit by looking through the orifice at the top of the unit or through the hole at the back near the burner If the flame...

Страница 11: ...or few hours Put it the right way up and connect again All repairs if needed particularly of the cooling unit or the gas burner system can only be carried out by a qualified technician If a problem oc...

Страница 12: ...G30 Butane G31 Propane and their Propane mixtures G30 Butane at 28 30 mbar 37 mbar 50 mbar 28 30 mbar G31 Propane at 37 mbar 150W 180W 180W 11 g h 13 g h 13 g h BE FR IT LU IE LU NL DK FI PL DE AT GB...

Страница 13: ...utane G31 G30 Butane G31 Propane and their Propane mixtures G30 Butane at 28 30 mbar 37 mbar 50 mbar 28 30 mbar G31 Propane at 37 mbar 180W 200W 13 g h 14 6 g h BE FR IT LU IE LU NL DK FI PL DE AT GB...

Страница 14: ...3 Door Shelf 4 Hinge lower right 5 Shelf 6 Shelf 7 Hinge lower left 8 Removable drip tray 9 Cooling flange 10 DC 12V switch 11 AC 230V switch 12 Rotary knob thermostat 13 Rotary knob gas 14 Indicator...

Страница 15: ...ection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment F...

Страница 16: ...support bluefintrading co uk www bluefinactive com...

Отзывы: