background image

TECHNICAL DATA

 

(cont.)

Item No.
Net capacity
Refrigerant
AC supply
DC supply 
Climate class 
Isolation 
Gas category 
Gas type 

Gas pressure 

 

 

 
Heat input 
Gas consumption
Destination country 

Gas cylinder

Gas hose

Gas regulator

This appliance belongs to type A

11

Read manufacturer’s instructions before use - this appliance shall be installed 

according to the rules in force.
To be used only in well-ventilated area, above ground and protected from rain.

XC-62GAS, FA60G 
60L 
Ammonia- NH

3,

 125g 

230V/50Hz, 100W, 0.43A 
12V, 100W, 8.33A 
N, SN 
Cyclopentane 
I3+(28~30/ 37) 

I3B/P(30)          I3B/P(37)          I3B/P(50)     

G30 (Butane), G31  G30 (Butane), G31 (Propane) and their

(Propane)  

mixtures

G30 (Butane) at 

28-30 mbar      37 mbar 

50 mbar

(28-30) mbar / G31 

(Propane) at 37 

mbar 
 

                     180W   

 

200W

 

                     13 g/h   

 

14.6 g/h

BE, FR, IT, LU, IE, 

LU, NL, DK, FI,    PL 

 

DE, AT,

GB, PT, ES, CY, CZ 

SE, CY, CZ, EE 

 

CH, LU,

LT, SK, CH, SI, LV 

LT, MT, SK, SI, 

 

SK

 

 

BG, IS, NO, TR,

 

 

HR, RO, IT, HU

  LV

Standard gas cylinder with maximum weight not exceeding 

15 kg (Maximum Dia. 320mm, Maximum height 550mm / 

below the gas connection). The cylinder shall comply with 

local code. The cylinder should be firmly fixed. Do not use 

or store near flammable or explosive products. 
Certified gas hose according to applicable EN-standard and 

comply with local code (max 1.5m / 1.2m in Finland).

NB/ It is necessary to change the hose when national 

conditions require it.
Certified regulator according to EN 12864

Содержание ACTIVE XC-43G

Страница 1: ...For use with BLUEFIN ACTIVE Absorption Refrigerator 12V 230V Gas Model XC 43G FA50G XC 62GAS FA60G...

Страница 2: ......

Страница 3: ...re with your device please read this manual carefully before operation The operational safety and function of the device can only be guaranteed if the general safety and accident preventionregulations...

Страница 4: ...t play with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 This appliance is intended for use as a cool box using with three ways source energy The thr...

Страница 5: ...farm houses and by clients in hotels motels and other residential type environments bed and breakfast type environments catering and similar non retail applications 13 For appliances have compartments...

Страница 6: ...e unit and the wall must be at least 10 cm The minimum distance to be observed on the sides shall be at least 5 cm Avoid placing the appliance in direct sunlight or near any source of heat Do not cove...

Страница 7: ...0V thermostat knob left clockwise to the position max After about one hour the effects of the cooling process become visible frost on the inside evaporator 4 The thermostat enables the temperature of...

Страница 8: ...t the engine 4 When using a battery as a power source there is no thermostatically temperature controller i e you cannot increase or decrease the temperature inside the fridge The cooling performance...

Страница 9: ...never in a basement or a cellar Protect from sunlight and do not expose to high temperatures 5 The appliance cannot operate at a pressure other than the one specified on the identification label at t...

Страница 10: ...the system which has to be forced out It is necessary to check that the pilot is lit by looking through the orifice at the top of the unit or through the hole at the back near the burner If the flame...

Страница 11: ...or few hours Put it the right way up and connect again All repairs if needed particularly of the cooling unit or the gas burner system can only be carried out by a qualified technician If a problem oc...

Страница 12: ...G30 Butane G31 Propane and their Propane mixtures G30 Butane at 28 30 mbar 37 mbar 50 mbar 28 30 mbar G31 Propane at 37 mbar 150W 180W 180W 11 g h 13 g h 13 g h BE FR IT LU IE LU NL DK FI PL DE AT GB...

Страница 13: ...utane G31 G30 Butane G31 Propane and their Propane mixtures G30 Butane at 28 30 mbar 37 mbar 50 mbar 28 30 mbar G31 Propane at 37 mbar 180W 200W 13 g h 14 6 g h BE FR IT LU IE LU NL DK FI PL DE AT GB...

Страница 14: ...3 Door Shelf 4 Hinge lower right 5 Shelf 6 Shelf 7 Hinge lower left 8 Removable drip tray 9 Cooling flange 10 DC 12V switch 11 AC 230V switch 12 Rotary knob thermostat 13 Rotary knob gas 14 Indicator...

Страница 15: ...ection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment F...

Страница 16: ...support bluefintrading co uk www bluefinactive com...

Отзывы: