background image

Work  station  series  for  solar  water  heating  control  system 

 

 

Ⅲ 

Functions and operation

 

Danger:

 Before connecting the power supply, make sure that the storage, solar collector, solar     

work station and all temperature sensors are good connected! 

 

1. Setting week and time 

After  power  supply  is  switched  on,  please  firstly  set  the         

week of the system. 

ì

  Press “System Setting” button until the signal “

” displays 

on the screen. 

ì

  Press  “+”  “-”  button  to  set  weekday.  (range:  0-6,  e.g.  1 

means “Monday”) 

ì

  Press “Confirm” button to save the setting; press “Cancel” 

button to cancel the setting. 

ì

  Press “System Setting” button again until “

” displays on 

the screen. 

ì

  Press “+” button to set hour, press “-” button to set minute. 

ì

  Press “Confirm” button to save the setting; press “Cancel” 

button to cancel the setting. 

2. Time-controlled auxiliary heating 

Solar thermal system can be combined with electric boiler or gas/oil boiler. The system is supported 

with  a  default  program which  can  be  customized  to meet  your  individual  needs.  You  can  create  a 

timer program with up to three  time periods to heat the water to  a desired value. During  the three 

preset  time  periods,  auxiliary  heating  starts  working,  when  the  water  temperature  in  top  part  of 

storage  (T3)  is  below  preset  turning-on  temperature,  and  it  stops  working,  when  T3  exceeds  the 

required temperature. 

 

Note:

  Default  setting:  the  first  time  period:  04:00     

turning-on,  05:00  turning-off;  the  second  time                   

period: 10:00~10:00; the third time period: 17:00 turning-on, 

22:00 turning-off. 

ì

  Press  “System  Setting”  button  until  the  signal  “

” 

appears. 

ì

  Press  “+”  “-”  button  to  set  the  start  time  of  the  first  time 

period. Press “+” to adjust hours, press “-” button to adjust minutes.   

ì

  Press “Confirm” button to save the settings, press “Cancel” button to cancel the settings. 

ì

  Immediately after setting the first time period, the display enters into the operating menu of next time 

period. 

ì

  Perform like above steps, the other two time periods can be set. 

Содержание sp116

Страница 1: ......

Страница 2: ...uction General information 1 Product description 2 Function description 5 Fault message 10 Part 2 Installation instruction General information 11 Mounting 12 Electrical wiring 14 Commissioning 15 Repl...

Страница 3: ...becomes evident that safe operation is no longer possible please immediately take the device out of operation Without lightning rod please don t use this device during a thunderstorm 3 Liability waiv...

Страница 4: ...ollector array 1 storage T1 Temperature sensor for collector array T2 Temperature sensor in bottom part of storage T3 Temperature sensor in top part of storage P1 Solar circulation pump P2 Solar circu...

Страница 5: ...ium flushing the pipeline 6 Circulation pump WILO Star RS 15 6 110V or 220V 7 Expansion vessel connector Connect expansion vessel Expansion vessel balances the system pressure 8 Return flow Copper mat...

Страница 6: ...ection grade IP40 4 Display signals Weekday 7days of week can be set e g Week 1 means Monday Time Setting hours and minutes Time controlled auxiliary heating Setting three heating time periods Time co...

Страница 7: ...or gas oil boiler The system is supported with a default program which can be customized to meet your individual needs You can create a timer program with up to three time periods to heat the water to...

Страница 8: ...tton to confirm the setting press Cancel button to cancel this setting Immediately after setting the first time period the display enters into the operating menu of next time period Perform like above...

Страница 9: ...temperature exceeds the switch off temperature of frost protection pump P1 stops working and the system exits frost protection Press System Setting until displays on the screen Press button to adjust...

Страница 10: ...tive Press Confirm button to confirm this setting Press Cancel button to deactivate this function Note When using holiday function system will lock auxiliary heating automatically 10 Anti bacteria pro...

Страница 11: ...main operating menu And when there are no other operations and it returns to main menu they can also activate some functions by pressing different buttons directly Press Confirm button 2 second to swi...

Страница 12: ...the pipeline and exhaust the air 6 Pump works but system doesn t have temp difference meanwhile auxiliary heating function starts up Frost protection function is activated signal blinks After collect...

Страница 13: ...s provided by the customer Damages by improper using or incorrect modification of installation and construction are on costumer site Attention This manual is for trained personals only Note As faults...

Страница 14: ...stem considering the mounting place for expansion vessel See picture 1 2 Drill the holes for dowels put the dowels into the holes fixed the solar control system on the wall using fastening screws The...

Страница 15: ...valve 6 After above steps connect an expansion vessel to the connector 7 See picture 6 7 Filling the system Connect a separate pump to the filling valve with pressure hose Open the filling and drain v...

Страница 16: ...ble blue for N line cable yellow green for the ground wire 3 To connect external circulation pumps or any electromagnetic valves firstly loose the aviation socket and dismount it as indicated below Co...

Страница 17: ...to relief the air 3 When the flow rate becomes regular observe the system pressure from manometer If the pressure is lower than 2 bars refill the system with heat medium to increase the pressure 4 Ca...

Страница 18: ...tor pump could be replaced if it gets broken Disconnect the power supply of solar control system Loose the screw and open the metal cover 2 Remove the front half of the insulation material from system...

Страница 19: ...es for solar water heating control system 17 5 Replace the old one with a new WILO pump 6 Fasten the WILO pump screws 7 Connect the power supply again and close the terminal box 8 Attach the front hal...

Страница 20: ...ontrol system 18 9 Attach the meal cover and fasten the screws again Packing list No Item Specification Quantity 1 Work station 380 220 140mm 1 pc 2 Power line 1 pc 3 PT1000 sensor 15m 1 pc 4 NTC sens...

Отзывы: