Work station series for solar water heating control system
5
Ⅲ
Functions and operation
Danger:
Before connecting the power supply, make sure that the storage, solar collector, solar
work station and all temperature sensors are good connected!
1. Setting week and time
After power supply is switched on, please firstly set the
week of the system.
ì
Press “System Setting” button until the signal “
” displays
on the screen.
ì
Press “+” “-” button to set weekday. (range: 0-6, e.g. 1
means “Monday”)
ì
Press “Confirm” button to save the setting; press “Cancel”
button to cancel the setting.
ì
Press “System Setting” button again until “
” displays on
the screen.
ì
Press “+” button to set hour, press “-” button to set minute.
ì
Press “Confirm” button to save the setting; press “Cancel”
button to cancel the setting.
2. Time-controlled auxiliary heating
Solar thermal system can be combined with electric boiler or gas/oil boiler. The system is supported
with a default program which can be customized to meet your individual needs. You can create a
timer program with up to three time periods to heat the water to a desired value. During the three
preset time periods, auxiliary heating starts working, when the water temperature in top part of
storage (T3) is below preset turning-on temperature, and it stops working, when T3 exceeds the
required temperature.
Note:
Default setting: the first time period: 04:00
turning-on, 05:00 turning-off; the second time
period: 10:00~10:00; the third time period: 17:00 turning-on,
22:00 turning-off.
ì
Press “System Setting” button until the signal “
”
appears.
ì
Press “+” “-” button to set the start time of the first time
period. Press “+” to adjust hours, press “-” button to adjust minutes.
ì
Press “Confirm” button to save the settings, press “Cancel” button to cancel the settings.
ì
Immediately after setting the first time period, the display enters into the operating menu of next time
period.
ì
Perform like above steps, the other two time periods can be set.