blueclean sp116 Скачать руководство пользователя страница 13

Work  station  series  for  solar  water  heating  control  system 

 

11 

Part 2: Installation instruction   

General information

 

1. Safety 

Before  installing  the  device,  please  read  this  manual  carefully.  Please  note  that  the  installation 

must  be  executed  according  to  relevant  technical  rules.  The  installation  must  be  adapted  to  the 

conditions  provided  by  the  customer.  Damages  by  improper  using  or  incorrect  modification  of 

installation and construction are on costumer site. 

 

Attention: 

This manual is for trained personals only! 

 

Note: 

As faults can never be excluded, we don’t offer a guarantee for the completeness of the 

drawings and texts of this manual, they only represent some examples.

 

2. Input and output signals

 

   

 

T1 connector 

P2 circulation pump connector 

T2 connector 

Power plug connector 

T3 connector 

Auxiliary heating connector 

3. System demonstration 

 

Содержание sp116

Страница 1: ......

Страница 2: ...uction General information 1 Product description 2 Function description 5 Fault message 10 Part 2 Installation instruction General information 11 Mounting 12 Electrical wiring 14 Commissioning 15 Repl...

Страница 3: ...becomes evident that safe operation is no longer possible please immediately take the device out of operation Without lightning rod please don t use this device during a thunderstorm 3 Liability waiv...

Страница 4: ...ollector array 1 storage T1 Temperature sensor for collector array T2 Temperature sensor in bottom part of storage T3 Temperature sensor in top part of storage P1 Solar circulation pump P2 Solar circu...

Страница 5: ...ium flushing the pipeline 6 Circulation pump WILO Star RS 15 6 110V or 220V 7 Expansion vessel connector Connect expansion vessel Expansion vessel balances the system pressure 8 Return flow Copper mat...

Страница 6: ...ection grade IP40 4 Display signals Weekday 7days of week can be set e g Week 1 means Monday Time Setting hours and minutes Time controlled auxiliary heating Setting three heating time periods Time co...

Страница 7: ...or gas oil boiler The system is supported with a default program which can be customized to meet your individual needs You can create a timer program with up to three time periods to heat the water to...

Страница 8: ...tton to confirm the setting press Cancel button to cancel this setting Immediately after setting the first time period the display enters into the operating menu of next time period Perform like above...

Страница 9: ...temperature exceeds the switch off temperature of frost protection pump P1 stops working and the system exits frost protection Press System Setting until displays on the screen Press button to adjust...

Страница 10: ...tive Press Confirm button to confirm this setting Press Cancel button to deactivate this function Note When using holiday function system will lock auxiliary heating automatically 10 Anti bacteria pro...

Страница 11: ...main operating menu And when there are no other operations and it returns to main menu they can also activate some functions by pressing different buttons directly Press Confirm button 2 second to swi...

Страница 12: ...the pipeline and exhaust the air 6 Pump works but system doesn t have temp difference meanwhile auxiliary heating function starts up Frost protection function is activated signal blinks After collect...

Страница 13: ...s provided by the customer Damages by improper using or incorrect modification of installation and construction are on costumer site Attention This manual is for trained personals only Note As faults...

Страница 14: ...stem considering the mounting place for expansion vessel See picture 1 2 Drill the holes for dowels put the dowels into the holes fixed the solar control system on the wall using fastening screws The...

Страница 15: ...valve 6 After above steps connect an expansion vessel to the connector 7 See picture 6 7 Filling the system Connect a separate pump to the filling valve with pressure hose Open the filling and drain v...

Страница 16: ...ble blue for N line cable yellow green for the ground wire 3 To connect external circulation pumps or any electromagnetic valves firstly loose the aviation socket and dismount it as indicated below Co...

Страница 17: ...to relief the air 3 When the flow rate becomes regular observe the system pressure from manometer If the pressure is lower than 2 bars refill the system with heat medium to increase the pressure 4 Ca...

Страница 18: ...tor pump could be replaced if it gets broken Disconnect the power supply of solar control system Loose the screw and open the metal cover 2 Remove the front half of the insulation material from system...

Страница 19: ...es for solar water heating control system 17 5 Replace the old one with a new WILO pump 6 Fasten the WILO pump screws 7 Connect the power supply again and close the terminal box 8 Attach the front hal...

Страница 20: ...ontrol system 18 9 Attach the meal cover and fasten the screws again Packing list No Item Specification Quantity 1 Work station 380 220 140mm 1 pc 2 Power line 1 pc 3 PT1000 sensor 15m 1 pc 4 NTC sens...