![BlueChip HB5 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/bluechip/hb5/hb5_technical-user-manual_2777430019.webp)
________________________________________________________________________________________________________________________________________________
31
0 volts
33
CTX3_P
COM Port 3 Transmit
COM 3 RS232 Transmit
level for RS422/485, RS232
levels for RS232
35
CTX3_N
COM Port 3 Transmit
/ COM 3 RS232 Receive
level for RS422/485, RS232
levels for RS232
37
CRX3_P
COM Port 3 Receive
3volts level for RS422/485,
RS232 levels for RS232
39
CRX3_N
COM Port 3 Receive
level for RS422/485, RS232
levels for RS232
41
0 volts
43
I2C SCL
I2C Clock at a 3 volts level
45
I2C SDA
I2C Data at a 3 volts level
47
0 volts
49
VIN
5 volts Power INPUT
with the main power in
connector on HB5
Notes:
1.
The details of the connector are:
a.
50 way 2mm pitch socket.
2.
The voltage level of all the GPIO lines can be changed from 3 volts to 1.8 volts in the kernel.
HB5 Touch Computer
____________________________________________________________________________________________________________________________________________
32
SPI CLK
SPI Clock
Transmit – Positive /
COM 3 RS232 Transmit – 3volts
level for RS422/485, RS232
34
SPI SIMO
SPI – Output when
COM Port 3 Transmit – Negative
/ COM 3 RS232 Receive – 3volts
level for RS422/485, RS232
36
0 volts
COM Port 3 Receive – Positive –
3volts level for RS422/485,
RS232 levels for RS232
38
PWROFF#
Apply logic low to power
down the unit
COM Port 3 Receive – 3volts
level for RS422/485, RS232
40
RESET#
Apply logic low to reset
the unit
42
SLEEP RQ#
Apply logic low while the
system in operational to
signal that the OS should
go into suspend. Apply
logic low while the system
in suspend wake up the
system.
I2C Clock at a 3 volts level
44
BOOT MODE#
Apply logic low during
power up to put the unit
into USB engineering
mode.
I2C Data at a 3 volts level
46
0 volts
48
VCC
3 volts
INPUT – in parallel
with the main power in
connector on HB5
50
RTC_BAT
Nominal 3.6 volts DC for
Real Time Clock
The details of the connector are:
50 way 2mm pitch socket.
The voltage level of all the GPIO lines can be changed from 3 volts to 1.8 volts in the kernel.
Touch Computer
_____________________________________
Page | 19
Output when Master
Apply logic low to power
down the unit
Apply logic low to reset
Apply logic low while the
system in operational to
signal that the OS should
go into suspend. Apply
while the system
in suspend wake up the
Apply logic low during
power up to put the unit
into USB engineering
Nominal 3.6 volts DC for
Real Time Clock
The voltage level of all the GPIO lines can be changed from 3 volts to 1.8 volts in the kernel.