3.3.5 Step 5: Configure the Region Setting
Configure the region if necessary. The region can be configured using the config system region command in
the BB Shell.
Note that FCC, ETSI, Japan, and Australia Readers cannot be altered and only operate per the regulatory
laws in USA/Canada, the European Union, Japan, and Australia.
Command1
Descriptions
region
Configure the region of Reader. ASCII characters are allowed.
You must use capital letters. You can only configure the region
defined in the region table.
The config system region command allows the user to configure Reader’s region.
ASCII characters are allowed. You must use capital letters. You can only configure the region defined in the
region table.
1
KOREA
9
INDIA
17 MOROCCO
25
THAILAND
2
ETSI
10
INDONESIA
18 NEW ZEALAND
26
URUGUAY
3
FCC
11
IRAN
19 PAKISTAN
27
VENEZUELA
4
AUSTRALIA
12
ISRAEL
20 PERU
28
VIETNAM
5
BANGLADESH
13
JAPAN_1
21 PHILIPPINES
29
RUSSIA
6
BRAZIL
14
JAPAN_2
22 SINGAPORE
30
ALGERIA
7
BRUNEI
15
JORDAN
23 SOUTH_AFRICA
31
EGYPT
8
CHINA
16
24 TAIWAN
32
CHILE
Table 3.1 region table
Example :
[FR900] config system $ region K
OREA
Return='0,Success'
3.3.6 Step 6: Test the Reader
Read the tag and verify that the connections and functions are correct. DemoApp, BLUEBIRD's Windows PC
test application, makes it easy to check Reader operation. Use DemoApp to configure various settings and
then run a simple inventory operatio