Preparations

Battery installation

1. Remove the cover of the battery slot by 

pressing the cover in the direction indicated 

by the embossment on the cover.

2. Place 2 AAA batteries in the battery slot as 

indicated by the embossment on the bottom 

of the battery slot. The negative battery 

terminals (-) go against the springs in the 

battery slot. 

3. Close the cover of the battery slot.

Battery replacement

The device detects the charge level of bat-

teries automatically and indicates a charge 

that is too low with a symbol. (battery symbol) 

The device retains the measurement memory 

for 30 seconds without batteries, so remove 

the new batteries from their packaging and 

place them next to the device before remov-

ing the old ones.

1. Remove the cover of the battery slot by 

pressing the cover in the direction indicated 

by the embossment on the cover.

2. Remove the old batteries and replace 

them with new ones. Replace both batteries 

at the same time.

3. Close the cover of the battery slot.

Note!

• The charge level of batteries decreases in 

cool air.

• Old batteries may damage the device, so 

when the device indicates a low charge level, 

remove the old batteries from the device and 

replace them with new ones.

• Do not leave batteries in the device for 

more than three months if you do not intend 

to use the device.

• Do not mix old and new batteries.

• If you accidentally place the batteries in 

the device the wrong way round, remove the 

batteries, wait for 1 minute and then place 

the batteries in the battery slot again the right 

way round.

• Recycle old batteries. They must not be 

burned as they may explode.

Recommendations for use

• Always measure blood pressure from the 

same wrist and in the same position.

• Measure blood pressure in room tempera-

ture.

• Measure at the same time in the morning, 

afternoon and evening. Three times a day.

• During measurement, hold the blood 

pressure monitor at heart level so that you are 

sitting up straight and supporting your elbow 

on a table, for example.

• You should be relaxed during measurement. 

30 minutes before measurement, you should 

refrain from going to sauna, bathing, exercis-

ing, smoking, eating, alcohol and products 

containing caffeine, such as coffee.

• The feeling of needing to urinate raises 

blood pressure. Go to the toilet before meas-

urement if you feel the need.

•  Calm down and relax for a few minutes 

while sitting in place prior to measurement.

• If you take several measurements at a time, 

have 5 minute breaks between the measure-

ments.

• The first measurement result is not reliable 

because several measurements over a longer 

period of time are required to detect the 

general level. 

• Keep a record of measurement results in the 

long term to gain more accurate information 

and, if necessary, to present them to your 

doctor.

Wrist cuff placement

1. Open the wrist cuff and place it around 

the left, bare wrist so that the display of the 

device is on the palm side. The palm and the 

device are pointed at you.

2. Ensure that the edge of the device is ap-

prox. 1 cm from the bottom of the palm.

3. Wrap the wrist cuff around the wrist with 

your right hand and fasten it at the Velcro 

tape.

Measuring position

1. Sit in a chair with your back straight and 

your feet firmly on the floor.

2. Support your elbow against a table so that 

the blood pressure monitor is at heart level. 

You can place a pillow under the elbow but 

the pillow must not put pressure on the wrist 

cuff.

3. Ensure that the palm and the blood pres-

sure monitor are facing you.

4. Let the hand and wrist rest in a relaxed 

position.

Taking a measurement

Measurement is started using the On/Off 

button and it can be interrupted at any time 

using the same button.

1. Press the On/Off button. The display of the 

device wakes up and all symbols light up 

momentarily on the display.

2. The device flashes the reading “00” a few 

times, after which the wrist cuff inflates and 

tightens. The reading on the display increases 

and reaches its peak.

3. The reading starts to gradually decrease 

while the wrist cuff deflates. The device beeps 

in time with the pulse while the reading on 

the display decreases.

4. When the measurement result is ready, the 

device will no longer flash the reading, but 

display the systolic pressure, diastolic pressure 

and pulse.

5. You can open the wrist cuff and remove the 

device from the wrist.

The measurement result is automatically 

saved in the device’s memory and the dis-

play/device turns itself off after a short while. 

You can also turn off the device using the 

On/Off button. It is a good idea to take a 5 

minute break before the next measurement. 

The second measurement result is often more 

accurate.

Warning!

• If the device malfunctions and the wrist cuff 

continues to tighten, remove the wrist cuff 

and turn off the device immediately.

• Do not use the device if you have injured 

your hand. Talk to your doctor first about 

using the device.

Viewing saved measurement results

1. Press the Memory button.

The device displays the most recent meas-

urement data. The number in the bottom left 

corner of the display indicates the memory 

slot (01–99).

2. You can browse the data of previous meas-

urements by pressing the Memory button 

again. The device saves 99 measurements, 

and when new measurements are taken, the 

device deletes the data of the oldest meas-

urements to make way for the new.

The display stays on for 9 seconds and then 

turns itself off if the Memory button is not 

pressed again, browsing saved measure-

ments. When the display is on, the device can 

also be turned off by pressing the Power (On/

Off) button.

Device cleaning and storage

You can wipe the device with a damp cloth 

if it is dirty. Place the wrist blood pressure mon-

itor and guide back into their packaging so 

that the wrist cuff is rolled up and the display 

of the monitor is facing upwards.

Remove the batteries from the battery slot if 

you do not intend to use the device for more 

than 3 months.

Device calibration

We do not offer recalibration of devices.

Technical specifications

Bluebiit Wrist blood pressure monitor

BBBP99WT1

Wrist cuff inflation: Automatic pump inflation

Wrist cuff deflation: Automatic

Display: LCD digital display (width 28 mm, height 35 mm)

Measurement method: Oscillographic method

Pressure measurement range: 20–280 mmHg (0.4–37.3 

kPa)

Pressure measurement accuracy: ±3 mmHg (±0.4 kPa)

Pulse measurement range: 40–199 beats/min.

Pulse measurement accuracy: ±5%

Operating temperature: 10–40°C, Maximum relative 

humidity 40–85%

Storage temperature: -20–50°C, Maximum relative 

humidity 15–90%

Power source: 2 AAA batteries (1.5V LR03)

Voltage: 3 V, Power: 1 W

Measurable wrist circumference: 135–195 mm

Measurements without wrist cuff: 73 mm × 70 mm × 32 

mm, Weight: 100 g (without batteries)

Package contents

Wrist blood pressure monitor, wrist cuff, protec-

tive cover and user guide