background image

7

Содержание BBB23-1B-HC

Страница 1: ...make product modification at any time Specifications and Designs are subject to change without notice IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTIONS Visit our website at www blueairfse com BBB23 1B 1S HC BBB59 2B 2S HC BBB69 3B 3S HC BBB90 4B 4S HC BBB23 1BG 1SG HC BBB59 2BG 2SG HC BBB69 3BG 3SG HC BBB90 4BG 4SG HC BDD23 1B 1S HC BDD59 2B 2S HC BDD69 3B 3S HC BDD90 4B 4S HC ...

Страница 2: ...t our website at www blueairfse com Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 Maintenance Cleaning _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ 6 Operation Caution Important _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Air Hose Tower Installation Schematic Diagram _ _ _ _ _ 7 Beer Line CO2 Line Installation Sc...

Страница 3: ... 1BG 1SG HC BBB59 2GB 2SG HC BBB69 3GB 3SG HC FBB90 4GB 4SG HC Capacity cu ft 7 9 19 4 23 4 31 6 Exterior Dimensions W 23 3 8 59 69 1 8 90 3 8 D 31 1 8 27 1 8 H 39 1 8 37 Doors 1 2 2 3 Shelves 2 4 4 6 Condensing Unit Size 1 4 HP 3 8 HP 3 8HP 3 8HP Electrical Characteristics 115V 60Hz NEMA Plug Configuration NEMA 5 15P Amps 3 0 3 5 3 5 3 5 Range of Temperature 32 F to 41 F Refrigerant R290 12oz Can...

Страница 4: ... CAUTION Risk of fire or explosion due to flammable refrigerant used Follow handling instructions carefully in compliance with U S and Canadian government PRODUCT Direct Darw Beer Dispenser Refrigeration Model Solid Door BDD23 1B 1S HC BDD59 2B 2S HC BDD69 3B 3S HC BDD90 4B 4S HC Capacity cu ft 7 9 19 4 23 4 31 6 Exterior Dimensions W 23 3 8 59 69 1 8 90 3 8 D 31 1 8 27 1 8 H 39 1 8 37 Doors 1 2 2...

Страница 5: ...ain proper sealing 1 INDOOR USE ONLY 1 This unit is intended for indoor use only 2 FOR LOCATION 1 Be sure that the location is strong enough to support the total weights of unit and the content 2 Keep the unit away from sunlight and other heat generating equipment 3 The minimum clearance between the back of the unit and wall should be 7 inches at least 3 INSTALLING CASTERS 1 Be sure that casters w...

Страница 6: ...ORMAL position at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of cabinet 5 The unit is equipped with an off cycle defrost Excessively opening the door will cause the breakdown Handle with care as shutting the door ...

Страница 7: ...7 ...

Страница 8: ...8 Assemble Beer Line CO2 Line as above drawing ...

Страница 9: ...ove the unit from direct sunlight Move the unit away from heat generating devices Install the unit in a well ventilated area with at least 7 Inches of clearance on all sides Clean the condenser if heavy dust is collected Clear contents from blocking the air duct in the interior Check the temperature controller for incorrect setting Check the refrigerant level it may need to be charged Check the do...

Страница 10: ...10 ...

Страница 11: ..._______________________ Extended Warranty Option Additional 1 Year Parts Labor extended Warranty available Please make check payable to TITAN and Return with this registration card 口 Yes I would like the extended warranty 口 No I would not like the extended warranty Signature of Business Owner ______________________________ Date _____________________ Zip ________ __ Customer Name __________________...

Страница 12: ...Blueair FSE LLC 223 W Rosecrans Ave Gardena CA 90248 Toll Free 1 866 677 8500 TEL 310 808 0102 FAX 310 808 0242 Visit our website at www blueairfse com ...

Отзывы: