14.0 Pump Maintenance
14.0 Pump Maintenance
Page 50
14.6 TFD
This pump is equipped with a Tube Failure Detecting System which is designed to stop the
pump and provide an output alarm (see Output menu) in the event pump the tube should
rupture and chemical enters the pump head.
This patented system is capable of detecting the presence of a large number of chemicals
including Sodium Hypochlorite (Chlorine), Hydrochloric (muriatic) Acid, Sodium Hydroxide,
and many others. The system will not be triggered by water (rain, condensation, etc.) or sili-
cone oil (roller and tubing lubricant).
If a TFD alarm occurs, the pump will stop and the screen will turn red with “TFD”
If TFD alarm occurs:
1. Remove the pump head cover, and the
pump tube and roller assembly.
2. Check for fluids at the bottom of the
pump head.
5. Carefully clean the chemical out of the
pump head. Ensure to remove all the
chemical traces from the sensor
probes.
3. Replace Tubing
3. Reinstall only the pump head cover.
4. Turn on the pump by pressing the
START button.
6. Reinstall the roller assembly and
tubing.
7. Reinstall the pump head cover.
8. Press the START button to clear the
alarm condition.
Chemical from tube failure
If TFD alarm occurs:
1
Remove the pump head cover,
pump tube and roller assembly
2
Check for fluids at the bottom of
the pump head
3
Carefully clean the chemical out
of the pump head. Especially
the sensor probes.
4
Replace the tubing
5
Reinstall only the pump head
cover
6
Turn on the pump by pressing
the START button
7
Reinstall the roller assembly
and tubing.
8
Reinstall the pump head cover
9
Press the START button to
clear the alarm condition
14.5 Tube Replacement
Insert suction fitting into pump head. Remove your fingers from
pump head. Start pump by pressing START button. Grab hold of
Tube Installation Tool and use it to leverage tubing into pump head.
Introduce tubing into pump head while the rotor is rotating. Avoid
using fingers to guide the tubing. Stop pump at anytime by
pressing STOP button. Start pump by pressing START button.
Continue to follow rotation of rotor while directing tube into pump
head. At this point, you may need to pull Tube Installation Tool to
stretch tubing into position. Let rotor spin a few rotations while
pulling Installation tool so fitting can be properly installed.
1
2
3
PULL
4
!
CAUTION
Prior to service, pump clean water through the pump and suction / discharge line to remove
chemical.
Always wear protective clothing, face shield, safety glasses and gloves when working on
or near your metering pump. Additional precautions should be taken depending on
solution being pumped. Refer to MSDS precautions from your solution supplier.
!
CAUTION
Use provided Tube Installation Tool to leverage tubing into pump head, NOT YOUR
FINGERS.
!
CAUTION
Use extreme caution when replacing pump tube. Be careful of your fingers and DO NOT
place fingers near rollers.
!
CAUTION
Continue to pull Tube Installation Tool to allow enough room to
slide discharge fitting into pump head tongue and groove. Once
discharge fitting is secured in pump head, stop pump by pressing
STOP button. Replace pump head cover. Pump will ask you if the
tube was replaced, select yes. Pump will then ask if you would like
to reset REV counter, select yes. REV count will display for 5
seconds before resetting to zero.
Содержание FLEXFLO M3 Series
Страница 1: ...Peristaltic Metering Pump Series M3...
Страница 6: ...2 0 Engineering Specifications Page 6 FLEXFLO M3...
Страница 8: ...3 1 Non Wetted Components 3 2 Wetted Components Page 8 FLEXFLO M3 3 0 Materials of Construction...
Страница 31: ...Page 31 FLEXFLO M3 10 0 Industrial Protocols 10 1 Control and Status Mapping for Industrial Protocols...
Страница 52: ...FLEXFLO M3 15 0 Replacement Parts List Page 52...
Страница 53: ...Page 53 FLEXFLO M3 16 0 Tubing Information...
Страница 56: ...FLEXFLO M3 Page 56 PAGE INTENTIONALLY LEFT BLANK...
Страница 59: ...Page 59 FLEXFLO M3...