5.4 How To Install the Tubing and Fittings
!
Inlet Tubing -
Locate the inlet fitting of the Pump Tube. Remove the tube
nut. Push the clear PVC suction tubing onto the compression barb of the
fitting. Use the tube nut to secure the tube. Hand tighten only.
CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.
Foot
Strainer
Ceramic
Weight
Tubing
Suction 3/8"
!
Strainer
- Trim the inlet end of the suction tubing so that
the strainer will rest approximately two inches from the
bottom of the solution tank. This will prevent sediment
from clogging the strainer. Slip the ceramic weight over the
end of the suction tube. Press the strainer into the end of
the tube. Secure the ceramic weight to the strainer. Drop
the strainer into the solution tank.
!
Outlet Tubing -
Locate the outlet fitting of the Pump
Tube. Remove the tube nut. Push the opaque outlet
(discharge) tubing onto the compression barb of the fitting.
Use the tube nut to secure the tube. Hand tighten only.
Keep outlet tube as short as possible.
!
Injection/Check Valve Fitting Installation
- The
Injection/Check valve fitting is designed to install directly
into either 1/4” or 1/2” female pipe threads. This fitting will
require periodic cleaning, especially when injecting fluids
that calcify such as sodium hypochlorite. See section 7.0.
Install the Injection/Check valve directly into the piping
system. To prevent trapped gasses, install the fitting in an
upward direction. Use Teflon thread sealing tape on the pipe
threads.
Push the opaque outlet (discharge) tubing onto the compres-
sion barb of the Injection/Check valve fitting. Use the tube
nut to secure the tube. Hand tighten only.
Inlet Adapter
Outlet Adapter
Pump Head
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - 0-1000 Hz
PROGRAM
RESET SERVICE
PRIME
DISPLAY
DIGITAL TIMER PUMP
1
VDC
SERVICE
1000
ALARM
mA
Hz
MODE
TFDFVS
ON-TTOT-TSECMINHRDAY
5 - PULSE (BATCH)
Содержание FLEXFLO A-100NE
Страница 23: ...A 100NE Page 23 THIS PAGE BLANK ...