background image

PSIg / BAR

Temperature

80°F / 26.7°C

100°F / 37.8°C

120°F / 48.9°C

140°F / 60.0°C

160°F / 71.1°C

180°F / 82.2°C

200°F / 93.3°C

220°F / 104.4°C

0 / 0

30 / 2.07

60 / 4.14

90 / 6.21

120 / 8.27

150 / 10.34

Catalog Number

Description

 

Qty

Item

1

1

2

2

6

76001-012

90007-158

Union Nut (PVC)

Union Nut (ALUM)

2

2

76001-037

.50” FPT Adpapter (PVC)

2

76001-004

.50” FPT Adapter (PVDF)

2

-

Body (PSF) 

1

3

91001-146

Float Stop (PSF)

2

1

2

3

4

5

6

4

90003-023

O-ring (Viton)*

1

5

-

Float (PTFE)

1

2

2

76001-042

.75” FPT Adpapter (PVC)

2

76000-982

.75” FPT Adapter (PVDF)

2

Page 2

Page 3

F-460

F-460

PVC Fittings

PVDF Fittings

Scale

Permanent dual scale silkscreen

Max Pressure

See Temperature vs. Pressure chart*

Max Temperature

See Temperature vs. Pressure chart*

Height

10” (25.4 cm)

Width

1.75” (4.45 cm)

Accuracy

± 2.5% of full scale reading

5

3

4

3

1  The  flowmeter  must  be  installed  in  a 
vertical  plane  to  ensure  accuracy. 

Misalignment  may  damage  the  flowmeter 
and also may cause the o-ring seals to leak.

2  Use  only  PTFE  tape  on  the  threaded 
adapters.

 Pipe dope and glue will damage 

the polysulfone meter body and fittings. Or 
install  the  flowmeter  after  all  glued  fittings 
have  dried  and  fumes  have  been  purged 
from the system.

3  Mounts  and  supports  must  be  sturdy 
enough  to  support  the  plumbing  and 
prevent  vibration. 

Vibration  and  heavy 

loads will damage the meter. 

4  Avoid imposing a sudden burst of flow 
to the meter.

 Solenoid valves will damage 

the meter. Such a burst will cause the float to 
impact  the  top  float  stop  with  destructive 
force.

5  The  Maximum  fluid  temperature  is 
dependant on the working pressure.

 High 

pressure and temperature with damage the 
meter. (see temperature VS pressure chart)

TEMPERATURE vs PRESSURE

INSTALLATION GUIDE

EXPLODED VIEW, PARTS LIST AND SPECS

METER SPECS

PARTS LIST

EXPLODED VIEW

APPLICATION NOTES

Although meters may be suitable for other chemicals, Blue-White cannot 
guarantee their suitability. It is the responsibility of the user to determine  the 
suitability of the flowmeter in their application. 

Flowmeters are tested and 

calibrated for water only.

MAINTENANCE

The “Exploded View” drawing illustrates assembly of the F-460 series meter. 
If  your  flowmeter  needs  to  be  cleaned  refer  to  this    drawing  when 
reassembling the unit. The tapered tube may be cleaned with a soft   bottle 
brush. Use a MILD soap and water solution for cleaning purposes. Note the 
float’s “up” position.

*EP Option Available

ALUM = Aluminum
PSF= Polysulfone
PVC = Polyvinyl chloride
PVDF = Polyvinylidene fluoride

2

1

Отзывы: